TECHNICAL DATA
Power to fi rebox
Power to water
Yield
CO emission at 10% O
2
Smoke temperature
Fuel consumption
Draft
Water content
Max water operating pressure
Max H
O operating temperature
2
Water side load loss
Heatable volume *
Ø smoke pipe (male)
Weight with packaging
TECHNICAL DATA FOR CHIMNEY FLUE DIMENSIONING which must however comply with the instructions in the
data sheet and the installation standards of each product
Power to fi rebox
Smoke outlet temperature on dis-
charge
Minimum draft
Smoke capacity
* The heatable volume is calculated considering home insulation pursuant to L 10/91 and subsequent amendments
and a heating requirement of 33 Kcal/m³ per hour.
* It is important to also take into consideration the location of the boiler in the environment to heat.
ELECTRICAL CHARACTERISTICS
Power supply
On/off switch
Average absorbed power
Protection on electronic board
The data outlined above are approximate and relate to the certifi cation phase carried out by the notifi ed body.
EDILKAMIN s.p.a. reserves the right to change the products without prior notifi cation at its discretion.
N.B.:
- Changes made by unauthorised staff are forbidden
- Use spare parts recommended by the manufacturer
- Use of non-original spare parts causes the warranty to expire
GENERAL INFORMATION
LAGUNA W 25
29.1
22.6
77.7
31
118
6.3
0.12 - 0.05
112
2
90
200 a ΔT = 20 K - 750 at ΔT = 10 K
590
150
430
LAGUNA W 25
29.1
142
0 - 0.05
12.4
- 48
LAGUNA W 35
0.12 - 0.05
200 a ΔT = 20 K - 750 at ΔT = 10 K
LAGUNA W 35
230Vac +/- 10% 50 Hz
yes
120 W
Fuse T6,3A, 250 Vac 5x20
-
34.7
kW
26.9
kW
77.6
%
32
mg/m
130
°C
7.5
kg/h
mbar
128
Litres
2
bar
90
°C
mbar
700
m
150
mm
530
kg
34.07
kW
156
°C
0 - 0.05
mbar
17.4
g/s
3
3