ROOF VENT WITH STEEL CHIMNEY FLUE
In installation of the chimney fl ue, always guar-
antee an inspection door to enable periodic
cleaning of soot and a condensate collector
with drainage to evacuate any condensate.
If the smoke pipe is installed completely exter-
nally, you should make it fully in stainless steel
with a double wall to guarantee better resist-
ance to atmospheric agents and adequate
temperature of the smoke vent.
ROOF VENT WITH TRADITIONAL CHIMNEY
FLUE
Combustion gas can also be evacuated using
an existing, traditional chimney fl ue provided it
is built to standard.
It must comply with the following regulations:
• it must be equipped with adequate insulation
in the exposed external section;
• the internal section must be constant;
• it must be created using material resistant to
high temperatures, the action of combustion
products and any condensate that could form;
• mainly vertical progression with deviation from
the axis not over 45°;
• it must have a soot and condensate collection
chamber which can be inspected via a door.
INSTALLATION
- 56
-
CHIMNEY
STACK
NON-COMBUSTIBLE
INSULATION
INSULATE THE
SMOKE VENT
INSPECTION DOOR
CONTAINER
FOR SOOT
WITH DRAINAGE
FOR CONDEN-
SATE
CHIMNEY
STACK
NON-COMBUSTIBLE
INSULATION
INSPECTION DOOR
CONTAINER
FOR SOOT
WITH DRAINAGE
FOR CONDEN-
SATE