EdilKamin BASIC PLUS Instalación Uso Y Mantenimiento página 29

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
• COMPONENTS - SAFETY AND DETECTION DEVICES
Smoke thermocouple
on the smoke outlet. It reads the smoke temperature. It regula-
tes the ignition stage and shuts the boiler-fi replace down if the
temperature is too high or too low (SF o AL 07).
Flow sensor
Positioned in the aspiration channel, the sensor stops the boiler
when the fl ow of comburent air is incorrect (and which could
cause the consequent risk of problems of depression in the
fumes circuit).
Mechanical pressure switch
The pressure switch stops the supply of pellets if the fi replace
door is opened or if the fl ue is blocked.
Feed Screw safety thermostat
Placed near the pellet hopper. It disconnects the electrical sup-
ply to the gear motor if the temperature detected is too high.
Water temperature detector
It reads the water temperature in the boiler and sends the circuit
board information for pump management and boiler power
modulation.
If the temperature is too high, it starts a shutdown.
Water overheating safety thermostat
detects the water temperature in the thermo-stoves. If this is
too high, it triggers the shutdown process by disconnecting the
electrical supply to the gear motor.
If the thermostat has been tripped it must be reset using the re-
set button behind the boiler after having removed the protective
cap
(A - fi g. 1).
Overpressure valve 3 bar
Upon reaching the pressure stipulated on the plate, the system
is triggered to discharge the water and consequently the water
must be topped up.
WARNING!!!! remember to carry out the connection with the
sewage system.
Resistance
It sets off of the combustion of the pellets and it remains lit until
the fl ame has been ignited. This component is subject to wear
Smoke extractor
"Pushes" the smoke into the fl ue and draws out combustion air
via a vacuum.
Vacuum gauge (electronic pressure sensor):
positioned on the smoke extractor, which detects the vacuum
value (compared to the installation environment) in the combu-
stion chamber.
N.B.:
IF THE BOILER BLOCKS, THE REASON WILL APPEAR ON THE DISPLAY AND THIS WILL BE SAVED.
FEATURES
Tank safety thermostat:
Located on the system that loads the pellets from the hopper.
Trips when the temperature inside the boiler-fi replac is too high.
It stops pellet loading, causing the boiler-fi replace to go out.
Pump (electronic circulator see page 37)
"Pushes" water toward the heating system.
Closed expansion tank
"absorbs" the variations in the volume of water contained insi-
de the boiler-fi replace due to the heating effect.
The subject issuing the declaration of conformity must con-
sider whether an extra tank is necessary, according to the
total volume of water contained in the system!
Gear motor
Activate the feed screw, which allows the pellets to be transfer-
red from the hopper to the combustion chamber.
Manometer
positioned on the inner front of the stove (opening cover B -
fi g. 2), and shows the pressure of the water in the boiler.
The recommended pressure is 1.5 bar when the boiler is on.
Drain tap
Positioned on the rear of the boiler, this should be opened when
the water inside the boiler must be emptied.
Manual bleed valve
Positioned on the inner front of the boiler (opening the door
- page 33), This allows bleeding of any air present after the boi-
ler has been fi lled with water.
A
fi g. 1
fi g. 2
- 29
-
B

Publicidad

Tabla de contenido
loading

Tabla de contenido