The control unit has a number of optional functions to enable the user to
add specific functionalities to the automation, thus personalising the prod-
uct according to special needs.
10 – AUTOMATION OPERATION ADJUSTMENT
To personalise operation of the automation, a number of functions can be
enabled or disabled, also with the option for modifications to settings as
required. The functions are:
• AUTOMATIC LEAF CLOSURE When this function is enabled, at the
end of an Opening manoeuvre activated by the client, the control unit
automatically closes the gate after a set time interval.
• LEAF MOVEMENT SPEED This function enables the user to set the
required speed used by the automation to move the gate leafs.
• LEAF SENSITIVITY TO OBSTACLES During a manoeuvre, if an obsta-
cle accidentally stops gate leaf movement (a gust of wind, a vehicle, per-
son etc.) this function promptly detects the increase in motor stress to
contract the obstacle and activates immediate and total inversion of
movement. If "automatic leaf closure" is set, the control unit re-attempts
the movement a second time and on the third time, after a brief inversion,
it stops the manoeuvre permanently.
• LEAF PRESSURE DISCHARGE At the end of the Closing manoeuvre,
after the leafs have reached limit switch "0", the motor continues to "push"
the leafs for a brief interval, to ensure perfect closure. Immediately after-
wards, this function activates a very brief inversion of movement, to
reduce excessive pressure exerted by the motor on the leafs
The values of these functions can be set according to personal require-
ments using the following procedure with a transmitter that has at least
one key already memorised on the control unit.
Note – During this procedure, each time a key is pressed the flashing light
emits one flash.
01. Press and hold the keys "T1" and "T2" simultaneously on the trans-
mitter for at least 5 seconds, after which release.
The two leds (green and red) on the Control unit flash to indicate entry
to function programming mode (the leds continue to flash throughout
the procedure).
02. Press and hold a transmitter key (already memorised on that of the
control unit) for at least 1 second (the green Led emits one flash).
03. Then select one of the four functions available and on the transmitter
press the key associated with the function for at least 1 second (the
green Led emits one flash):
• Automatic leaf closure = (press key "T1")
• Leaf movement speed = (press key "T2")
• Leaf sensitivity to obstacles = (press key "T3")
• leaf pressure discharge = (press key "T4")
04. Lastly, refer to Table 4, select the required value in correspondence
with the selected function and on the transmitter press the key asso-
ciated with the selected value for at least 1 second (the green and
red Leds emit one confirmation flash).
24 – English

ADJUSTMENTS AND OTHER OPTIONAL FUNCTIONS

TABLE 4
Automatic leaf closure
No closure—> (press key "T1")
Closure after 15 seconds —> (press key "T2")
Closure after 30 seconds —> (press key "T3")
Closure after 60 seconds —> (press key "T4")
Leaf movement speed
Low —> (press key "T1")
Medium low —> (press key "T2")
Medium high —> (press key "T3")
High —> (press key "T4")
Leaf SENSITIVITY TO OBSTACLES
High —> (press key "T1")
Medium high —> (press key "T2")
Medium low —> (press key "T3")
Low —> (press key "T4")
Leaf PRESSURE DISCHARGE
No discharge —> (press key "T1")
Minimum —> (press key "T2")
Medium —> (press key "T3")
Maximum —> (press key "T4")
Notes to Table 4:
– The Table states the values available for each of the 4 special functions
and the corresponding key to be pressed on the transmitter for selection
of the specific value.
– The factory settings are highlighted in grey.
– In caso di mancanza dell'energia elettrica, al ripristino della corrente la
prima manovra comandata verrà eseguita dall'automazione a velocità
ridotta, indipendentemente dal tipo di velocità impostata.
11 – MEMORISING A NEW TRANSMITTER WITH
PROCEDURE IN THE VICINITY OF THE CONTROL
UNIT [with a transmitter already memorised]
A NEW transmitter can be memorised in the control unit memory without
acting directly on key P1 of the control unit, but by simply working within
its reception range. To use this procedure, an OLD transmitter, previously
memorised and operative, is required. The procedure enables the NEW
transmitter to receive the settings of the OLD version.
Warning – The procedure must be performed within the reception
range of the receiver (maximum 10-20 m from receiver).
01. On the NEW transmitter, press and hold the key to be memorised for
at least 5 seconds and then release.
02. On the OLD transmitter, slowly press the control key to be memo-
rised on the other transmitter 3 times.
03. On the NEW transmitter, press the same key pressed in point 01
once.
Note – Repeat the same procedure for each key to be memorised.
12 – DELETING DATA FROM THE CONTROL UNIT MEMORY
Data in the control unit memory can be deleted partially or totally as
required. To do this, the following procedures can be used, as required:
• Deletion of a command on a transmitter already memorised
• Deletion of other data memorised on the control unit