CAUTION! – Strictly observe the electrical connections specified in
this paragraph, as incorrect connections could lead to serious faults
or hazards.
If the distance of the gate from the electrical mains is greater than the
length of the power cable supplied, this cable may be replaced with an
electric line that is adequately protected and suited to the application.
In this case, use a power cable with the dimensions 3 x 1,5 mm
maximum length of 30 m. For greater lengths, use a cable with a larger
section: For example , 3 x 2,5 mm
ty of the automation. Then proceed as follows:
To connect the new cable to the Control unit:
01. Fig. A - Remove the cover from the gearmotor with control unit,
loosening the two lateral screws with a screwdriver.
A
02. Fig. B e C – Loosen the power cable clamp, loosen the screw of the
terminal board cover using a Phillips screwdriver and remove the
existing cable. Then fix the new cable to the terminal board, observ-
To connect the new cable to the electrical mains:
CAUTION! – When making this connection, the electrical mains power line must be equipped with short-circuit protection device (between the
automation and the mains).
The electrical mains line must also be equipped with a power disconnect device (with overvoltage category III, i.e. minimum gap between contacts of
3.5 mm) or an equivalent system such as socket with removable plug.
This device, when necessary, guarantees fast and safe disconnection of the power supply and therefore must be placed in a location visible from the
automation. If the power disconnect device is not in the vicinity of the automation and not visible from the latter, it must be fitted with a lockout facili-
ty to prevent inadvertent or unauthorised connection.
Note – The disconnect devices are not supplied with the product.
26 – English

Tasks reserved for qualified technicians

CAUTION! – All operations in this section must be performed exclusively by skilled and quali-
fied personnel, in observance of the instructions in the manual, and current local legislation and
safety standards in the place of installation.
CONNECTING THE AUTOMATION TO THE ELECTRICAL MAINS
USING A CABLE OTHER THAN THE VERSION SUPPLIED
2
, ensuring safety earthing in the vicini-
ing the relative symbols. Note – the terminal board can be removed
from its seat to facilitate wiring.
– Brown wire, to connect to "Phase"
– Blue wire, to connect to "Neutral"
– Yellow-green wire, to connect to "Earth"
B
2
, and
C
03. Then refit the terminal board cover and close the gearmotor with its
cover.a