Tabla De Contenido; Warranty; Installation; Location & Assembly - Scotsman FME804 Indicaciones Para El Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
User Manual for
Modular Ice Flakers
models
FME804 - FME1204 -
NME654 - NME954
TABLE OF CONTENTS
Warranty . . . . . . . . . . . . . . . page 2
Installation . . . . . . . . . . . . . . page 2
Plumbing . . . . . . . . . . . . . . . page 3
Electrical . . . . . . . . . . . . . . . page 3
Final Check List . . . . . . . . . . . . page 3
Initial Start Up . . . . . . . . . . . . page 3
Maintenance. . . . . . . . . . . . . . page 4
Failure Analysis . . . . . . . . . . . . page 4

WARRANTY:

The warranty conditions are those supplied by the official
distributor for your area. In case of parts, only GENUINE
service parts may be used.
TO INSTALL THE MACHINE
This machine is designed to fit the following Scotsman
storage bins:
B 390 or BH 550
A bin top kit is used to fit the machine to the bin. Check
sales information for proper kit.
INSTALLATION LIMITATIONS:
This ice system is designed to be installed indoors, in a
controlled environment:
Min
Air Temperature
Water Temperature
Water Pressure
Voltage
(Compared to the nameplate)
Operating the machine outside of the limitations is misuse
and can void any warranty.
Scotsman Ice Systems are designed and manufactured with
the highest regard for safety and performance.
Scotsman reserves the right to make design changes and/or
improvements at any time.
Specifications and design are subject to change without
notice.
LOCATION & ASSEMBLY:
After uncrating and inspection, the unit is ready for
installation. It is important that the machine be installed in a
location where it has enough space around it to be
accessible for service, and minimum of 150 mm be allowed
at the back for air circulation on air cooled models. Try to
avoid hot, dirty and crowded locations.
Storage Bin:
Tip the storage bin on its back, using parts of the carton to
protect the exterior finish. Install the legs into the threaded
holes in the bottom of the bin. Turn the leg levelers all the
way in preparation for leveling later. Return the bin to the
upright position, remove any paper covering the bin gasket.
Note: Do not push bin into position, but lift it there.
Pushing a bin, especially one with ice in it, can cause
damage to the legs and the leg mounts.
Install the appropriate bin top on the bin, according to the
instructions for the bin top.
Ice Maker:
The machine is heavy, so the use of a mechanical lift is
recommended for lifting the machine high enough to install
on top of the bin. After the unit is on the bin, align it with
the back. Secure it to the bin with the hardware provided
with the machine.

PLUMBING:

PLUMBING CONNECTIONS MUST
CONFORM TO ALL APPLICABLE CODES
Water Inlet
Air Cooled Models: The recommended water supply is
clean, cold water. Use 3/8" O.D. copper tubing, connect
to the 3/8" male flare at the back of the cabinet. Install a
hand valve near the machine to control the water supply.
2
Max
o
o
10
C
40
C
o
o
5
C
40
C
1 bar
5 bar
-5%
+10%

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fme1204Nme654Nme954

Tabla de contenido