CAUTION! – Incorrect connections can cause faults or hazards;
therefore ensure that the specified connections in this paragraph are
strictly observed.
In the case of this product, the cable supplied may need to be replaced
with a protected electric line suited to the installation.
In this case, use a power cable with the dimensions 3 x 1,5 mm
maximum length of 30 m. For greater lengths, use a cable with a larger
section: For example , 3 x 2,5 mm
of the automation. Then proceed as follows.
To connect the new cable to the Control unit:
01. Fig. A - Remove the gearmotor cover using a screwdriver to loosen
the 4 lateral screws.
A
To connect the new cable to the electrical mains:
ACAUTION! – When making this connection, the electrical mains power line must be equipped with short-circuit protection device (between the
automation and the mains).
The electrical mains line must also be equipped with a power disconnect device (with overvoltage category III, i.e. minimum gap between contacts of
3.5 mm) or an equivalent system such as socket with removable plug.
This device, when necessary, guarantees fast and safe disconnection of the power supply and therefore must be placed in a location visible from the
automation. If the power disconnect device is not in the vicinity of the automation and not visible from the latter, it must be fitted with a lockout facility
to prevent inadvertent or unauthorised connection.
Note – The disconnect devices are not supplied with the product.
24 – English
Tasks reserved for qualified technicians
CAUTION! – All operations in this section must be performed exclusively by skilled and qualified
personnel, in observance of the instructions in the manual, and current local legislation and safe-
ty standards in the place of installation.
CONNECTING THE AUTOMATION TO THE ELECTRICAL MAINS
WITH A CABLE OTHER THAN THE VERSION SUPPLIED
2
, ensuring safety earthing in the vicinity
02. Fig. B - Loosen the power cable clamp, loosen the screw of the ter-
minal board cover using a Phillips screwdriver and remove the exist-
ing cable. Then fix the new cable to the terminal board, observing the
relative symbols. Note – the terminal board can be removed from its
seat to facilitate wiring.
– Brown wire, to connect to "Phase";
2
, and
– Blue wire, to connect to "Neutral";
– Yellow-green wire, to connect to "Earth".
B
03. Then refit the terminal board cover and close the gearmotor with its
cover.