Kübler Group
Electrical characteristics sensor
Supply voltage
Supply voltage according to UL 1310
Supply voltage according to EN 60950
Current consumption
Protection class according to EN 61140 III
Safety data
Relevant Standards
Classification
PFHd value
Service life
EMC
Relevant Standards
UL - Underwriters Laboratories
UL approval
Relevant Standards
CAN Characteristics
Protocol
Transmission interval
Baud rate
Terminated
Max. distance to an evaluation unit
For further information, refer to the Ants LES02 CAN manual.

3.4.2 Coded Band

Material
Dimensions
Weight
Thermal expansion
BA Ants LES02 - R60073.0009 - 02
10 ... 30 V DC
Class 2
PELV
max. 100 mA
EN 81-20:2014
EN 81-50:2014
SIL3
-8
-1
< 1 x 10
 h
20 years
EN 12015:2014
EN 12016:2013
File E498900
UL 508
Proprietary
every 2 ms
250 kbits
yes
100 m (CAN bus),
twisted pair 0.5 mm2, with shield
V2A spring-tensioned stainless steel, edges broken
16 x 0.4 mm
50 g / m
-6
16 x 10
 / K