Kübler Group
5.2 Status LED
A two-color LED signals the status of the measuring system:
Display
LED off
LED green
LED green flashing
LED red
LED red flashing
5.3 Parameterizing
The measuring system can only be parameterized when the elevator plant system is entirely
connected.
NOTICE
5.4 Error mode reset
In the event of an error, an error code is issued and the measuring system locks itself (Locked
mode), and no more positions are sent. In this case, the sensor can only be reset by an evalu-
ation unit. The evaluation unit can also be a part of the elevator control which can/is allowed to
perform the reset.
The error processing routines must in any case be performed and complied with. See the de-
scription of the exchange protocol in the LES02 manual.
NOTICE
6 Maintenance
In harsh environments, we recommend regular inspections for firm seating and possible dam-
ages at the device. Repair work may only be carried out by the manufacturer, see chapter
Contact [} 51].
Prior to the work
1.
Switch off the power supply and secure it against switching on again.
2.
Then disconnect the power supply lines physically.
BA Ants LES02 - R60073.0009 - 02
LED
Meaning
No voltage
Supply voltage is applied to the device
Communication with the bus present
The sensor is in locked mode
An error that did not lead to the locked mode occurred
Other applicable manuals
Comply with the further relevant documentation such as data sheet,
operation manual and sensor manual, as well as with the corres-
ponding documents of the evaluation unit or of the elevator control.
Other applicable manuals
Comply with the further relevant documentation such as data sheet,
operation manual and sensor manual, as well as with the corres-
ponding documents of the evaluation unit or of the elevator control.