Periodic Inspection; Traceability; Replacing Single Components; Replacing The Slides - Kübler Ants LES02 Manual De Instrucciones

Ocultar thumbs Ver también para Ants LES02:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 104
6 Maintenance
3.
Remove operating and auxiliary materials and remaining processing materials from the
measuring system.

6.1 Periodic Inspection

ATTENTION
In order to ensure the reliable operation of the measuring system, the components must be
checked at regular intervals (at least once a year).
• Check the slides for excessive wear or dirt. Replace them if necessary, see chapter
Replacing the Slides [} 48].
• Clean the sensor and the coded band, see chapter Cleaning the Measuring System [} 49].
• Check the coded band for damages and foreign bodies.
A functional check must be carried out before continuing to use the system:
• Check the tight and proper seating of the rail fastening plates and the fastening of the sensor.
• Check the tension of the coded band based on the extension of the spring.
• Make sure that the coded band is properly guided between the slides, see
Step-By-Step Installation [} 43].
• Finally check and clean the coded band by removing the dirt with a cloth during an inspection
run. Do not use a cloth that would leave new dirt such as lint in the holes.

6.2 Traceability

NOTICE

6.3 Replacing Single Components

Defective or damaged devices and device parts can only be replaced as a whole. Exclusively
the slides and their fastening components can be replaced.

6.3.1 Replacing the Slides

NOTICE
48 - EN
Danger due to an unrecoverable defect
Note that, in the event of unrecoverable defects, the facility shall no
longer be operated. In case of doubt, contact the
manufacturer [} 51].
Identification of errors in the field
A traceability of these products is recommended. This can be
achieved for example by means of the serial number on the type
plate. Complete traceability is decisive for fast and targeted reaction
in the market
Locking element check
Replace the locking element if it shows traces of bending or break-
age (order code: 8.LEX.ZB.0013).
BA Ants LES02 - R60073.0009 - 02
Kübler Group

Publicidad

Tabla de contenido
loading

Productos relacionados para Kübler Ants LES02

Tabla de contenido