CHANNELLING
The insert has an opening on the left side (see location p. 21
DIMENSIONS) to channel hot air into an adjoining room or the
same room as the fireplace using a specific KIT (No. 7, cod. n.
290420) consisting of:
• hose clamp
• 3 m long Ø 10 flexible hose
• nozzle
It is important to remember the importance of suitable air tube
insulation to prevent heat dispersion and air cooling.
Illustrative picture
Avoid bends in the tube itself as far as possible. The channelling must not be plugged to avoid overheating. The air must
in any case be released into the room where the insert is found or into an adjacent room.
NOTES ON COVERING ASSEMBLY
Insert
To decide the exact location of Pellbox, the type of covering it will be completed with must be considered.
The insert must be positioned in a different way according to the model chosen (consult the assembly instructions pro-
vided in the packaging of each covering).
During installation, always check plumb and level.
Fasten the supporting frame provided to the floor, with plugs, in order to prevent possible overturning (see fig. 3, p. 23)
when the firebox door is opened for maintenance.
Coverings and structure around the hood, and their ventilation
Before fitting the covering, make sure the connections, controls and all moving parts work correctly.
This check must be done with the fireplace on and working steadily for a few hours, so that any necessary corrective ope-
rations may be carried out before covering the insert.
Consequently, finishing operations, such as building work around the hood, covering assembly, erection of pilasters,
painting, etc., must only be carried out if the tests are passed.
EdilKamin is in no case liable for costs deriving from the removal of these works or their rebuilding, even if it is neces-
sary in order to replace faulty parts.
Wooden parts must be protected with fire retardant panels, not come into contact with the insert itself, and be a suitable
distance from it (at least 1 cm so that air may flow and prevent heat build-up).
The structure around the hood may be built of fire retardant panels made of plasterboard or sheets of plaster; air circula-
tion grilles must be provided as previously described when these are built.
IT IS ESSENTIAL TO ASSURE AIR REPLENISHMENT
WITH THE TWO 36 X 9 CM GRILLES PROVIDED
ON THE FRONT AND/OR ON THE RIGHT SIDE
(looking at the fireplace from the front)
Besides the above, bear in mind the instructions in sections 4.4 and 4.7 of UNI standard 10683/2005 "insulation, finishes
and safety recommendations".
NOTE
If you do not wish to channel hot air into an adjacent room, it must in any case be channelled into the room where
the Pellbox SCF is installed.
Do NOT channel hot air into the building work around the hood or covering since this would lead to dangerous
overheating.
24