Daily Maintenance - EdilKamin INPELLET 49 Instalación Uso Y Mantenimiento

Ocultar thumbs Ver también para INPELLET 49:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
MAINTENANCE
Before performing any maintenance, disconnect the appliance from the mains.
Regular maintenance is re uired for the insert to function correctly.
LACK OF MAINTENANCE will prevent the insert from functioning properly.
Any problems resulting from lack of maintenance will immediately void the warranty.

DAILY MAINTENANCE

Operations must be performed when the stove is off, cold and unplugged from the power supply
ust be performed using a vacuum cleaner (see optional e tras page 9).
The whole procedure ta es up a few minutes every day.
- acuum the hatch, the re surface, and the compartment around the combustion chamber where the ash falls.
DO NOT EMPTY THE RESIDUE OUT INTO THE PELLET HOPPER.
- Remove the combustion chamber and use the metal spatula supplied to scrape off any waste. lean out any bloc ed holes on both sides.
- acuum the combustion chamber, clean the contacts between the chamber and its housing, replace the combustion chamber.
- lean the glass, if necessary (when cold).
Never vacuum hot ash, it can make the vacuum cleaner breakdown and puts the household rooms at risk of re
EEKLY MAINTENANCE
- lean the hearth and the chamber under the hearth (1) ( g. no.1).
- Remove and clean the ceiling ( ) ( g. no. ).
2
g. 1
g.
SEASONAL MAINTENANCE (IMPLEMENTED BY THE DEALER)
fter consumption of 1
g of pellets (modi able by the Dealer during 1st ignition), the wording maintenance will appear,
entailing the following:
- lean generally inside and out
- lean/ e change pipe carefully
- lean and remove dirt from combustion chamber
and relative compartment carefully
- lean the smo e outlet "A"
(replace smo e outlet pipe gas ets if necessary).
- lean smo e e traction fan compartment,
ow sensor and thermo coupling control "C".
- lean, inspect and scrape residues from the
ignition resistance compartment, replace if
necessary "D".
C
- isual inspection of electrical wires, connections
and power lead
- lean the pellet tan , removing the ange and
D
verify feed screw-gear motor assembly clearances
- Replace hatch seal if required
- Test function, cochlea load, ignition and function
A
for 1 minutes, then shutdown.
If the insert is used very fre uently, the smoke
duct should be cleaned once every 3 months.
- 36
-