POSSIBLE TROUBLESHOOTING
8) Signalling:
Check button
Problem:
signals an anomaly on the emergency button
Actions:
chec maintenance status of the button and its board connection cable.
) Signalling:
Battery check"
Problem:
The insert does not stop but the error appears on the display.
Actions:
The buffer battery of the control board needs changing (DE LER). Remember that it is a component
sub ect to wear.
0) Problem:
Remote control not working
Actions:
closer to the receiver of the insert
chec the battery and if necessary, replace it.
) Problem:
Outlet air not hot
Actions:
clean heat e changer from inside the rebo .
NOTA
All signals/warnings remain shown until you intervene on the remote control, by pressing the button
Do not use the insert before having eliminated the problem.
It is important to tell the Dealer e actly what the panel signals.
NOTA 2
After 000 kg of pellets consumed, the display ashes the wording Mainten.'.
The insert works, but you must call the Dealer out to perform e traordinary maintenance.
NOTA 3
If due to the uality of pellets or particularly critical installation, the insert becomes clogged earlier, the message CALL
SERVICE" will appear. Proceed as per "Mainten." instructions.
N.B.:
The combustion chambers and smoke ducts connected to the solid fuel appliances must be cleaned once a year (check if your
country has speci c legislation covering this .
ailure to regularly check and clean increases the likelihood of a re in the chimney pot.
In that case, proceed as follows:
do not shutdown with water;
empty the pellet tank;
contact specialised staff before restarting the machine.