RP 330 Pressing Tool
RP 330 Pressing Tools
Cleaning and Lubrication
1. Daily wipe the tool clean with a clean dry cloth.
2. Inspect the attachment mounting pin and lubricate the
pin with silicone lubricant as needed.
3. Check return springs in attachments with each use.
Attachments should open and close freely with only
moderate finger effort required.
Required Maintenance at RIDGID
Authorized Service Center
After 30,000 cycles, the tool will show a blinking yellow
LED on the display panel as long as the tool is turned on
to indicate that it is time for maintenance and recalibration.
The tool will not run if it is not maintained within 2,000
more cycles after the yellow blinking LED begins.
Accessories
WARNING
Only the following tool accessories have been de-
signed to function with the RP 330 Pressing Tools.
Other accessories suitable for use with other tools
may become hazardous when used on the RP 330.
To prevent serious injury, use only the accessories
specifically designed and recommended for use
with the RP 330, such as those listed below.
Ridge Tool Company provides Standard Pressing
attachments designed specifically for use with
RIDGID Standard Pressing tools. Only use attach-
ments that are specifically designed to press the fit-
ting system you are installing. For a complete listing
of RIDGID attachments available for this tool, see
the Ridge Tool Catalog on line at www.RIDGID.com
or call Ridge Tool Technical Services (800) 519-
3456.
RP 330 Press Tool Accessories
Catalog
No.
Description
27968
18V Lithium-Ion Battery Pack 2.2Ah
27958
115V Charger
27933
Carrying Case (Plastic)
Storage
Place the tool and jaws in its carrying case. Avoid storing
the tool, batteries or charger in extreme heat or cold.
The tool temperature sensor will not allow the tool to
turn on if oil temperature is not within the temperature
range of 15°F (-10°C) to 122°F (50°C). So it may be
necessary to allow the tool to warm or cool to a temper-
10
ature within the operating range by placing it in a condi-
tioned room for several minutes before use. This will be
indicated by a red glowing LED on the display panel.
WARNING
locked area that is out of reach of children and people
unfamiliar with the RP 330 Pressing Tool. The tool is
dangerous in the hands of untrained users.
Service and Repair
Improper service or repair can make machine
unsafe to operate.
Service and repair on this RP 330 Pressing Tool must be
performed by a RIDGID Authorized Service Center. The
tool fasteners have been marked to indicate if service has
been performed by unauthorized individuals.
For any repairs or maintenance, contact the Ridge Tool
Company, Technical Service Department at (800) 519-
3456 or www.RIDGID.com for nearest authorized ser-
vice outlet.
If you have any questions regarding the service or repair
of this machine, call or write to:
Ridge Tool Company
Technical Service Department
400 Clark Street
Elyria, Ohio 44035-6001
Tel: (800) 519-3456
E-mail: TechServices@ridgid.com
For name and address of your nearest Independent
Authorized Service Center, contact the Ridge Tool Com-
pany at (800) 519-3456 or http://www.RIDGID.com
Ridge Tool Company
Store the carrying case in a dry, secured,
WARNING