Floor and walls

The floor on which the appliance is placed must have
sufficient bearing capacity. The weight of the appli-
ance is given in the appendix "Technical Data
appendix".
Protect flammable flooring from heat radiation
by means of a fireproof protective plate. See
the appendix "Distance from combustible
material".
Remove combustible material such as lino-
leum, carpets/rugs and similar materials below
the fireproof protective plate.
Keep sufficient distance between the appli-
ance and combustible materials such as
wooden walls and furniture.
The connecting tube also radiates heat. Ensure
that there is sufficient distance or a shield
between the connecting tube and combustible
material.
The rule of thumb for a single-walled tube is a
distance of 3x the diameter. If a lining shell is
fitted around the tube, a distance of 1x the dia-
meter is permissible.
Carpets and rugs must be at least 80 cm away
from the fire.
Use a fireproof floor plate to protect a flam-
mable floor from any ash which may fall in front
of the stove. The floor plate must comply with
national standards.
For the dimensions of the fireproof protective
plate: see the appendix "Distance from com-
bustible material".
For further requirements with respect to fire
safety, see the appendix "Distance from com-
bustible material".
8

Product description

11
12
2
13
3
4
6
5
7
1. Connection collar
2. heat shield
3. Door
4. Bottom of the fire compartment
5. Latch
6. Air slide
7. Connection to outside air
8. Support
9. Adjustable feet
10. Extension (optional)
11. Stays (optional)
Subject to change because of technical improvements