AKG C535 EB Modo De Empleo página 27

Ocultar thumbs Ver también para C535 EB:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Use a small screwdriver or similar object to adjust the desired
switch position.
Figure 1: Mode switch
The switch offers four different positions:
0 dB
1
condenser microphone output level (7 mV/Pa), flat, over-
load limit: 130 dB SPL.
0 dB
2
condenser microphone level (as above) with bass-cut filter
below 100 Hz slope: 12 dB/octave.
Applications: mainly instrumental recordings, for reducing
unwanted low frequency structureborne noise.
-14 dB
3
attenuation of –14 dB, dynamic microphone output level,
flat, overload limit: 144 dB SPL.
Applications: recording high sound level instruments, or
prevention of overloading of mixer or amplifier inputs which
are adjusted for dynamic microphones.
C535 EB MANUAL
1
2
3
4
dEScRIPTIoN
27

Publicidad

Tabla de contenido
loading