7) By using the lines drawn previously as a guide, position the
compensators on the wall and check their perpendicularity. Then fas-
ten them with 6 (3+3) screws and 6 (3+3) washers.
Wall panel installation
Remove the methacrylate panel from its packaging. Since this oper-
ation is to be carried out standing on the shower base, it is advis-
able to cover it with suitable protection.
i
I
(
8) Position the panel on the shower base's edge by align-
ing the shower base frame's holes with the matching holes in the
panel's frame.
Fasten the two components together with 6 (3+3) screws, 6
(3+3) washers and 6 (3+3) indented washers.
i
(
9, detail 1) Be sure that the overflow hose coming
from the tank is positioned above the shower base.
I
The fabric-finish hose coming from the side connection of the
drainage column must be connected to the drain of the heater
tank by means of a plastic band - supplied in the hardware bag.
Then check that the band on the side connection of the drainage
column is fastened tight.
i
I
(
9, detail 3) When installing models with the "Power Fall"
waterfall function (ELT8 and ELT19 BT), position the O-Ring (band-
ed on the hose) into the plastic pipe fitting located on the waterfall
delivery line. Then screw the ring nut tightly to the pump fitting.
Glass panels installation
i
I
(
1) Remove the sliding glass panel from the packaging as
well as the sealing strips in transparent plastic (detail A), the upper
and lower slide guides (detail B and C) and the two fixed glass
panels with the two uprights (detail D).
i
I
(
10, detail 1) Apply silicone along the whole length of the
grooves of the lower and upper profiles of the fixed glass panels
and assemble them to the slide guides by means of 4 (2+2) self-
tapping screws. Use ONLY neutral silicone (not acetic).
i
I
(
10, detail 2) Attach the fixed glass panels' uprights to the
slide guides with 8 (2+2+2+2) self-tapping screws.
i
I
(
11) Position the assembled parts on the shower base and
verify whether:
- the lower slide guide's groove fits into the shower base's
raised edge (detail 1)
- the fixed glass panels' uprights fit properly into the aluminum
profiles attached to the methacrylate panel (detail 2).
i
I
(
11, detail 2) Attach the glass panels group to the wall
tracks with 10 (5+5) self-tapping screws.
i
I
(
12, detail 1) Fasten the glass panels' group to the shower
base with 3 metal brackets, supplied in the hardware bag) by in-
serting them first into the groove of the glass panels' lower guide
and then fastening them to the shower base frame with 3
(1+1+1) self-tapping screws and just as many indented washers.
I
Insert the two sealing strips (
el and fit it into the slide guide by inserting first the upper rollers
and then the lower rollers. (
rollers as well fit into the corresponding slide guide.
i
I
(
12) Check that the panels are perfectly perpendicular and
that they slide with ease. Should the sliding panel need to be ad-
justed, loosen the screw blocking the ball-grip on the roller, rotate
as necessary and then tighten the screw duly.
Top installation
i
I
(
13) Place the top on the shower enclosure so that the edge
fits into the groove of the upper slide guide and the rear edge is
laid upon the wall's metal frame: the top is then fastened to the
wall's metal frame with 4 (2+2) screws and 4 (2+2) washers.
i
I
(
13) Now connect the hose of the shower head to the cor-
responding solenoid valve mounted on the rear part of the seat
side panel: use the metal band. Do not tighten too much, other-
wise the hose risks being cut.
Hydraulic and electrical connections
I
Move the shower enclosure close enough to the wall to enable the
connection of flexible hoses to the outlets prepared in the wall.
I
Strictly follow the instructions in the "Electrical Safety"
chapter and the related wiring diagrams.
- Follow the L-phase, N neutral and
- Remove the lid of the electric wiring box as shown and, after hav-
ing connected, close the lid carefully and tighten the cable
clamps well, in order to guarantee protection from water jets.
IMPORTANT: for Countries where 220-240V voltage
is supplied by a two-phase system (L+L), the connec-
tion has to be made on terminals L and N anyway.
Electrical connections (models ELT4):
i
(
14) an electrical junction box is located in the rear part of the
shower base. Remove the cover and carry out the following con-
nection operations:
- connect the supply cable from the electronic control box
(marked with the label "P10"), to the terminal board of the
wiring junction box.
- then connect the power supply cable from the main electrical
network.
Electrical connections (models ELT8 and ELT19 BT):
i
(
14) at the back of the shower tray frame there is a wiring
junction box; cut the clip (detail 1) and fasten the box to the
bracket using the screws as shown.
Then remove the lid and connect as follows:
- connect the pump cable, marked with the " 2 " label, to the wi-
ring junction box.
- connect the dry reverse run to the corresponding cable (
14, detail A).
12
i
1, detail A) in the sliding pan-
i
12) Finally, check that the lower
earth symbols.