On the X-axis the time variables references are showed. At the bottom right
corner, the capture elapsed time is displayed, in seconds. At the bottom center the
T.span defines the seconds that will be displayed on the screen. For example, if the
T.span is 60s, therefore the last 60s captured, will be displayed on the screen. At the left
corner the time variable can be "end - time (s)" or "begin + time (s)".
The tag "end" indicates how many seconds you are from the last capture. To
select this option, go to the configuration menu and select the temporal reference "end".
The tag "begin" indicates how many seconds you are from when starting the
capture. To select this option, go to the configuration menu and select the temporal
reference "beginning".
On the Y-axis are placed the carriers. In this axis the initial and final carriers are
showed and depend on the 8k/4k/2k mode. Next to the final carrier the number of carrier
and the MER level where the cursor are placed is showed.
To move among the parameters press the cursor keys UP or DOWN.
To change a parameter, press the arrow keys LEFT or RIGHT or use the rotary
selector.
5.17.2.1
MEROGRAM Configuration
Before the capture begins the options must be configured. Press the key,
[17] and the option menu will be displayed.
Page 80
USER'S MANUAL. TV EXPLORER HD+
Figure 57.- First screen.
11/2013