Acquisition Function (Datalogger) - Promax TV EXPLORER HD+ Manual De Instrucciones

Explorador universal de tv
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USER'S MANUAL. TV EXPLORER HD+
5.10

Acquisition function (Datalogger)

The Datalogger function allows the user to carry out and store measurements in a
fully automatic way. It can store for each acquisition the measurements made in different
points of the installation. The measurements made are relevant to the current analogue
or digital channel, in the active channel plan.
To select the Datalogger function, activate the UTILITIES
select the RUN DATALOGGER option. Later, by turning the rotary selector [1] select a
previously stored acquisition (for instance, if you want to keep making measurements on
a different point test but in the same installation) or a NEW DATALOGGER.
During analogue channel measuring process, a percentage counter appears at the
bottom of the screen showing the percentage of channel measurement done. In the case
of digital channels, appears a timer showing time left to finish in seconds. At the top left
corner appears the channel being measured followed by the total amount of channels in
the current channel plan.
In order to select a field on the datalogger screen (Test point and datalogger
name), press the arrow
[1].
After selecting the START field the instrument begins to carry out the available
measurements automatically. Once completed, the process will be ready to repeat again
(START) (for example, for a new test point), to view measured data by selecting the
channel and turning the rotary selector
(SAVE) or to exit from this acquisition (EXIT).
11/2013
Figure 12.- DATALOGGER screen.
[6] key and then edit it by pressing the rotary selector
[1], to store the information in memory
[22] menu and
Page 37

Publicidad

Tabla de contenido
loading

Tabla de contenido