Installation; Installation Information; Installation Place; To Perfect Your Installation - mundoclima MUPIR-H8 Serie Manual De Instalación Y Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

INSTALLATION AND OWNER'S MANUAL

5. INSTALLATION

5.1 Installation information

The following information given here is not an instruction, but simply meant to give the
user a better understanding of the installation.

5.2 Installation place

Install the swimming pool heat pump on a flat, horizontal, and stable surface. Maintain 1
m of open space in front of the suction grids and 3 m on the outlet side of the ventilator.
And reserve enough space to allow access to controller.
Make sure that the discharged air will not be breathed in.

5.3 To perfect your installation

- Avoid directing the flow of ventilated air towards a sensitive noise zone, such as room
window.
- Avoid positioning pool heat pump on a surface that can transmit vibrations to dwelling.
- Try to avoid placing appliance under a tree or exposed to water or mud, which would be
likely to complicate maintenance.

5.4 Water connection

The heat pump is connected to a filtration circuit with a by-pass.
It is imperative that the by-pass is placed after the pump and the filter.
The by-pass generally consists of 3 valves.
This makes it possible to regulate the water flow which passes through the heat pump and
to isolate the heat pump completely for any maintenance work, without cutting the flow
of filtered water.
39

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido