DGE−...−ZR/−SP
If the motor turns in the wrong direction:
Note
When the motor is dismounted (e.g. turning the motor), the reference position
is lost.
· Start homing as detailed in the chapter Commissioning" in order to set the
new reference position.
8

Service and maintenance

Warning
Controller signals can cause the DGE to make unintentional movements.
· Switch off the controller for all maintenance work on the DGE and secure
·
Do not change screws and threaded pins if there is no direct request to do this
in these operating instructions.
·
If necessary, clean the cover band with a soft cloth.
The following cleaning agents are permitted: all non−abrasive cleaning agents.
·
Grease the surfaces of the guide rail
or cover band if they no longer have
a layer of grease.
Grease: in accordance with Fig. 41.
In this way you will renew the protection
against humidity.
·
Recommendation:
Return the DGE−...−ZR to Festo for inspection after every 5000 kilometres run.