Care And Maintenance - Festo DGCI Instrucciones De Utilizacion

Ocultar thumbs Ver también para DGCI:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
DGCI-...
8

Care and maintenance

Maintaining the band system
S
Clean the band system if required with a soft cloth.
The following cleaning agents are permitted: all non-abrasive media.
S
Lubricate the surface of the band system if it no longer has a layer of grease.
Grease type: LUB-KC1 (LUB-E1 for DGCI-...-H1).
Lubricating the recirculating ball bearing
guide KF:
The lubrication intervals S
the loading of the guide.
1. Calculate the load comparison factor fv
with the aid of the formula for combined
loads (
the lubricating interval S
S Always lubricate the DGCI at the latest
every 3 years (every 2 years for the
DGCI-...-H1).
S Note that lubrication must be undertaken more often in the case of:
– dusty and dirty environments
– working strokes < 50 mm or > 2000 mm
– at speeds > 2 m/s
– ambient temperatures > 40 °C.
2. Lubricate the roller bearing through the
holes on both sides of the slide.
For this purpose use a grease gun with
pinpoint nozzle or alternatively a dis-
posable syringe with needle.
Permitted types of grease:
DGCI:
DGCI-...-H1:
S Push the slide backwards and forwards during lubrication.
Otherwise the grease cavities will not be filled evenly.
Alternatively, Festo offers a service inspection which includes lubrication.
Otherwise the DGCI does not require any maintenance.
40
depend on
int
Technical data) and determine
from Fig. 26.
int
LUB-RN2
ELKALUB VP 874 (from Chemie-Technik)
DGC
DGC-H1
Fig. 26
Fig. 27
Festo DGCI-...-Z6 1207b English

Publicidad

Tabla de contenido
loading

Tabla de contenido