5.5. Integrated pH/ORP controller
The integrated pH/ORP controller is supplied with a default factory calibration and programmed with the following parameters:
pH SETPOINT="7.2"
ORP SETPOINT="750 mV"
IMPORTANT: In order for the pH to be regulated correctly, the Total Alkalinity of the pool water must be maintained in the range 80 – 120
ppm. Use a pool water test kit to check the Total Alkalinity and manually adjust if necessary.
5.5.1. CONNECTION OF THE PH/ORP SENSORS
Connect the pH and ORP sensors provided with the unit to the corresponding BNC connectors located in the base of the unit (Fig. 23).
5.5.2. CONNECTION OF THE DOSAGE PUMP
Astralpool Chlore Elite systems have a connector on their base for connecting a dosage pump to control the pH of the water in the pool. The
dosage pump can be connected through the CEE22 connector supplied for that purpose with the equipment (Fig. 23).
5.5.3. PH SETPOINT PROGRAMMING
Keep the "SET" [24] key pressed until the light displays the desired pH value within the 7.0 – 7.8 range. Release after selection.
Fig. 23
Fig. 24