Astralpool Elite 60 Manual De Instrucciones página 4

Sistema de electrolisis sauna
Ocultar thumbs Ver también para Elite 60:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
DESCRIPTION
Salt level protection
Measurement range
Control range
Precision
Calibration
Control outputs [pH]
pH/ORP sensors
Flow detector
3. SAFETY WARNINGS AND RECOMMENDATIONS:_____________________________________________________________________
The equipment should be assembled and handled by truly qualified people.
Current electrical and accident prevention regulations should be followed.
Under no circumstances will the manufacturer be held responsible for the assembly, installation or start-up, nor any handling or
fitting of components unless they are carried out on its premises.
The AstralPool Chlore Salt Electrolysis Systems (42353, 42354, 42355) operate at 230VAC, 50/60 Hz. Do not attempt to alter the
system to operate at a different voltage.
Check all the electrical connectors are well tightened to avoid false contacts and their consequent overheating.
Before installing or replacing any component, disconnect the equipment from the mains, and use exclusively spare parts supplied
by AstralPool.
Taking into account the fact that the equipment produces heat, it must be installed in places with sufficient ventilation. Fan
openings should be kept free of any element that could obstruct them. The equipment should not be installed near flammable
materials.
The AstralPool Chlore Salt Electrolysis Systems (42353, 42354, 42355) have a protection degree of IP24. They should never be
installed in places susceptible to flooding.
If the electrolysis equipment has no cover detection system, it is important to reduce its production to the minimum while the pool is
covered. Otherwise, an excess of chlorine could degrade the pool materials.
ELITE 60 – Code 42353
One output 230 V / 500 mA for dosage pump connection
PPO body, range 0 – 14 (pH) / ± 2000 mV (ORP), solid electrolyte
PPO Noryl GFN3 Casing / paddle, stainless steel 1,4571 shaft, EPDM O-ring
2
MODEL
ELITE 100 – Code 42354
Automatic production protection
0.0 – 9.9 (pH) / 0 – 999 mV (ORP)
7.0 – 7.8 (pH) / 650 – 800 mV (ORP)
± 0.1 pH / ± 1 mV (ORP)
Automatic with calibration solutions
ELITE 160 – Code 42355

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elite 100Elite 160423534235442355

Tabla de contenido