Astralpool Elite 60 Manual De Instrucciones página 17

Sistema de electrolisis sauna
Ocultar thumbs Ver también para Elite 60:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
5.5.4. ORP SETPOINT PROGRAMMING.
Keep the "SET" [26] key pressed until the light displays the desired ORP value within the 650 – 850 Mv range. Release after selection.
5.5.5. SAFETY STOP CONFIGURATION OF THE DOSAGE PUMP (PUMP-STOP FUNCTION)
The integrated pH controller has a security system (PUMP-STOP FUNCTION) acting on the dosage pump which allows to avoid the following
situations:
Damages caused by the dry operation of pump (depleted pH-minus product).
Over-dosage of pH-minus product (damaged or aged sensor).
PH regulation problems due to high alkalinity in the water (newly filled pool, high carbonate levels).
When the PUMP-STOP FUNCTION is enabled (factory default), the system stops the dosage pump after a programmed time without having
reached the pH setpoint.
The PUMP-STOP FUNCTION is factory set to 60 minutes. To change this value, follow the next procedure.
Fig. 25
Fig. 25b
15

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elite 100Elite 160423534235442355

Tabla de contenido