The plastic tongue (orange colour in fig. 3.1) and
groove guides on the top and bottom of the Bus
Terminal Controller and of the added I/O Modules
guarantees that the power contacts mate securely.
The load current of the "Power contact" must not
exceed 10 A for long periods.
The spring contact labelled PE can be used as a
protective earth. This contact is capacitive coupled
to the Bus Terminal Controller mounting rail.
3.4
Connectors.
X20 – CANopen (SSB interface).
X20
GB
X21 – Programming (COM 1 - RS 232).
X21
X310 – Profibus interface.
X310
18
Pin
Signal
1
reserved
2
CAN low
3
GND
4
reserved
5
shield
6
GND
7
CAN high
8
reserved
9
reserved
Pin
Interface
Signal
1
COM2
RS485 D+
2
COM1
RS232 TxD
3
COM1
RS232 RxD
4
VCC +5 V
VCC
5
GND
GND
6
COM2
RS485 D-
7
COM2
RS232 RxD
8
COM2
RS232 TxD
9
GND
GND
Pin
Signal
1
not used
2
not used
3
Profibus P signal
4
not used
5
GND
6
+ 5Vdc
7
not used
8
Profibus N signal
9
not used
3.5
Profibus Interface.
Network topology linear bus, with active bus
terminators at both ends.
Medium
shielded two twisted pair cable.
The screening may be required
by
conditions (EMC).
Transmission
speed
up to 12 Mbps, automatically
selected.
Maximum
bus length
400 m @ 500 Kbit/s. (100 m @
12 Mbit/s).
Connectors
Sub-D 9 poles, male.
NOTE: In order for the Power Source to be able to
interrupt the welding operation if there is
any heart bit in data transmission, the bus
node has a disconnection watchdog. If no
data transmission takes place within 1 s.,
all inputs and outputs are reset and the
Power Source is then in the stop state.
All Profibus signals coming from Power
Source
are
set
communication is not active.
3.6
Profibus cable.
The Bus Terminal Controller BX3100 has in the
left part the lodging for the Sub-D 9 poles
connector.
The Profibus cable, supplied with the equipment,
must be connected to this connector. The bus cable
is a 2x2 core twisted-conductor, screened cable;
one pair of cores is for data transmission, the other
pair is for the power supply.
The figure shows the Profibus cable connections.
The pin 3 is relative to the Profibus P signal.
The pin 5 is relative to the GND of the supply for
the line active terminator circuit.
The pin 6 is relative to +5 V
line active terminator circuit.
The pin 8 is relative to the Profibus N signal.
The cable screen must be connected to the Sub-D 9
poles connector shell. On the Bus Terminal
Controller BX3100 the connector body is coupled
to the DIN guide for assembly of the same module,
with a low resistance.
the
environmental
to
0
if
CANopen
of the supply for the
DC
3.300.185-D