Technical Information; Fluid Compatibility; Electrical Installation - FILL-RITE 400 Serie Manual De Operación Y Seguridad Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

•Santoprene diaphragms
•12 VDC, 24 VDC, 115 VAC/60 Hz, 230 VAC/50 Hz
available

TECHNICAL INFORMATION

Design Features
•1" FNPT straight inlet and 90
•15 PSIG maximum outlet pressure
•Explosion proof 2600 RPM, 1/4 HP motor:
•12 VDC, 20 amps maximum draw (5 amps
in full bypass)
•24 VDC, 10 amps maximum draw
•115 VAC/60 Hz rated at 1.5 amps
•230 VAC/50 Hz rated at 1.1 amps
•Thermal overload protection of the motor
•Quality ball bearing and needle bearing construction
•Positive displacement/self-priming design
•Unaffected by particulate materials up to 0.100"
diameter in the pumped fluids
•Flow easily controlled by outlet throttling from maximum
to zero
•Pump may run dry without damage
•Minimal surge action
•Handles viscosities from 1.0 CPS to 3000 CPS (SAE
140 gear oil at 68
•Minimum shear (agitation) of pumped fluids
•Does not include inlet strainer
•Minimum operating ambient temperature: -10ºF
(-23ºC)
•Maximum operating ambient temperature: 130ºF
(54ºC)
•Overall dimensions: 14" (35.6 cm) long x 8.25" (21cm)
high x 8.75" (22.2 cm) deep
Performance
•30 minute duty cycle, not for continuous operation
•9 inches (23 cm) of mercury dry vacuum
•Minimum suction lift: 10' (3 m) for water & 11' (3.3 m) for
diesel fuel. The lift is equivalent to the vertical
distance from the surface of the fluid in the tank to the inlet
of the pump, PLUS the friction losses through the vertical
and horizontal runs of pipe, all elbows and other fittings.
Systems should be designed to require a minimum
amount of suction lift.

Fluid Compatibility

The 400 Series pump is compatible with the following fluids:
Ethylene Glycol, Diesel fuel, Grease, Hydraulic Oil, Kero-
sene, Motor Oil, Water
The 400 Series pump is NOT compatible with the following
fluids:
Acetone, Ammonia, Gasoline, Bleach, Chlorine, Hydro-
chloric Acid, Ink, MEK
If in doubt about compatibility of a specific fluid, contact the
outlet standard
o
F)
o
supplier of the fluid to check for any adverse reactions to the
wetted materials shown in the parts list.
INSTALLATION
The basic pump is furnished with 1" NPT threaded openings in
the inlet and outlet flanges. Flanges are available as a straight
outlet or a 90
angle design, which can be rotated four ways to
o
accommodate different installation needs. Both inlet and
outlet flanges include four 1/4-20 threaded holes, spaced
apart 1 7/8" between centers, for secure mounting.
Mounting Holes
Adapters are available to fit the pump to a 2" bung and a
selection of standard bung fittings common in the petroleum,
chemical and agricultural markets.
1.
Assemble suction pipe.
2.
Screw suction pipe into bung adapter.
3.
Cut suction pipe at a length that will place its end
within 3” of the container bottom.
4.
Screw bung/suction pipe assembly securely into
container opening.
5.
Assemble pump onto bung adapter with 4 screws
(item 19).

Electrical Installation

Connect wires to pump as follows, paying special attention
to wire colors:
DC
Pump
Cable
Positive
Red
Negative
Black
Ground
Green
3
DANGER
Electrical wiring should be
done by a licensed electrician
in accordance with approved
electrical codes.
should be properly grounded
and a rigid conduit should be
used when installing electri-
cal wiring. Improper use or in-
stallation of this product can
cause serious bodily injury or
death.
AC
Pump
Leadwire
Hot
Neutral
Ground
Pump
Black
White
Green

Publicidad

Tabla de contenido
loading

Tabla de contenido