START-STOP BATTERY TEST
Press the ◄ ► key to select START-STOP Test.
1.
Press the ◄ ► key to select battery type:
2.
A.
AGM FLAT PLATE
B.
EFB (ENHANCED FLOODED)
C.
Press «ENTER» button to confirm
choice.
Press the ◄ ► key to select battery rating
3.
CCA/SAE, EN, IEC, or DIN. Press «ENTER»
button to confirm choice.
Press the ◄ ► key to input the battery
4.
capacity:
SAE (CCA): 25~3,000
EN: 25~2,830
DIN: 25~1,685
IEC: 25~1,985
Press «ENTER» to begin test.
Press the◄ ► key to confirm the location of
5.
the battery if a surface charge is detected,
follow the tester 's introductions to remove the
surface charge.
6.
Aim the "Temperature Measurement sensor"
2.5cm (1 inch) from the top or sides of the
battery case and press <<ENETR>>. Measured
-
-
5