Technical data

Parameter
Value
Housing material
Anodized die‑cast alloy
Degree of protection
acc. to IEC 60529
Cable entry
IP67
Plug connector
IP65
Mechanical life
1 x 10
operating cycles
6
Ambient temperature
‑25 ... +80 °C
Degree of contamination
(external, according to
3 (industrial)
EN 60947‑1)
Installation position
Any
Approach speed, max.
20 m/min
Extraction force (not locked)
30 N
Retention force
10 N
Actuating force, max.
35 N
Actuation frequency
1200/h
Switching principle
Slow‑action switching contact
Contact material
Silver alloy, gold flashed
Connection
TZ...
Cable entry M20 x 1.5
TZ...SR6
Plug connector SR6, 6‑pin+PE
TZ...SR11
Plug connector SR11, 11‑pin+PE
TZ...RC18
Plug connector RC18, 18‑pin+PE
Conductor cross‑section
0.34 ... 1.5 mm²
(flexible/rigid)
Rated insulation voltage
TZ...M, TZ...SR6
U
= 250 V
i
TZ...SR11
U
= 50 V
i
TZ...RC18
U
= 110 V
i
Rated impulse withstand voltage
TZ...M, TZ...SR6
U
= 2.5 kV
imp
TZ...SR11, TZ...RC18
U
= 1.5 kV
imp
Conditional short‑circuit
100 A
current
Switching voltage, min.,
12 V
at 10 mA
Utilization category acc. to EN 60947‑5‑1
TZ...M, TZ...SR6
AC‑15 4 A 230 V /
DC‑13 4 A 24 V
TZ...SR11
AC‑15 4 A 50 V /
DC‑13 4 A 24 V
TZ...RC18
AC‑15 4 A 110 V /
DC‑13 4 A 24 V
Switching current, min.,
1 mA
at 24 V
Short circuit protection
(control circuit fuse)
4 A gG
acc. to IEC 60269‑1
Conv. thermal current I
4 A
th
Solenoid operating voltage/solenoid power consumption
TZ...024
AC/DC 24 V (+10%/‑15%) 10 W
TZ...110
AC
110 V (+10%/‑15%) 10 W
TZ...230
AC
230 V (+10%/‑15%) 10 W
Duty cycle
100 %
Locking force F
F
= 2000 N
max
S
F
Locking force F
max
Zh
(F
=
) = 1500 N
Zh
acc. to EN ISO 14119
1.3
Limitations at ambient temperature above +70 ... +80 °C
Utilization category acc. to EN 60947‑5‑1
TZ...SR6
AC‑15 2 A 230 V /
DC‑13 2 A 24 V
TZ...SR11
AC‑15 2 A 50 V /
DC‑13 2 A 24 V
Conv. thermal current I
2 A
th
Short circuit protection
2 A gG
according to IEC 60269‑1
Reliability values acc. to EN ISO 13849-1
B
3 x 10
6
10d
8
Shown: Safety guard closed, actuator locked
TZ..SR6
TZ..SR11
SK
SK
21
22
6
21
22
8
6
13
14
2
9
13
14
3
UK
UK
21
22
3
10
21
22
1
1
13
14
11
13
14
7
1
2
1
2
LED GN
LED GN
5
6
5
6
5
LED RD
LED RD
3
4
3
4
4
5
4
2
PE
PE
TZ..RC18...C1826
SK
1
41
42
2
11
33
34
5
3
21
22
4
11
12
UK
7
41
42
8
13
33
34
14
9
21
22
10
17
13
14
18
1
2
15
LED GN
5
6
16
LED RD
4
3
6
19
PE/12
TZ..SR6
TZ..SR11
5
4
3
6
3
2
2
1
1
TZ..RC18
12
11
1
18
10
2
17
13
19
9
3
16
14
8
4
15
7
5
6
View on the connection side of the safety switch
Figure 3: Connector assignments
TZ..RC18
SK
1
41
42
2
11
33
34
19
3
21
22
6
11
12
UK
7
41
42
8
13
33
34
14
9
21
22
10
17
13
14
18
1
2
15
LED GN
5
6
16
LED RD
4
3
4
5
PE/12
4
5
10
6
7
9
11
8