Encoder; Flashing Light - V2 CITY1-EVO Manual De Usuario

Cuadro de maniobras digital para cancelas batientes y puertas correderas
Ocultar thumbs Ver también para CITY1-EVO:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.8 - ENCODER

With CITY1-EVO, you can use encoder-equipped motors to
control the exact position of the gates. Furthermore, the encoders
allow you to detect if the gate panels jam in an improper position
due to obstacles.
m
For correct operation of the encoders, it is essential
that both gate leaves rest against a mechanical stop when
in the closed position.
Upon every switching on of the control unit, the first START
control closes the gate to realign the encoders (if automatic
closing is active this operation occurs automatically).
m
ATTENTION: Limit switches entry terminals are used
to connect the encoders. Therefore, it is not possible to
connect simultaneously 2 motors with limit switches and
encoder.
m
WARNING: the sensor cables must not be run in the
same conduit as the motor cables.
m
WARNING: the encoders must be connected as
indicated below. Improper connection of the black cable
may damage the device.
CONNECTION OF TWO MOTORS WITH ENCODERS
• Connect the negative feeds (BLACK cable) for both encoders to
terminal E5
• Connect the positive feeds (RED cable) for both encoders to
terminal Z5
• Connect the motor 1 encoder signal cables (BLUE / WHITE) to
terminals E3 and E4
• Connect the motor 2 encoder signal cables (BLUE / WHITE) to
terminals E1 and E2
C
To activate the function, change the settings of parameter
EnCo
E1 E2 E3 E4 E5
ENCODER
ENCODER
M2
M1
Z1 Z2 Z3 Z4 Z5 Z6
12Vdc
- 40 -
CONNECTION OF ONE MOTOR WITH ENCODER AND
LIMIT SWITHCES
Installation of encoder
• Connect the negative feeds (BLACK cable) to terminal E5
• Connect the positive feeds (RED cable) to terminal Z5
• Connect the encoder output (BLUE / WHITE) to terminals
E3 and E4
C
To activate the function, change the settings of parameter
EnCo
Installation of limit switch
• Connect the open limit switch to terminals E1 and E5
• Connect the close limit switch to terminals E2 and E5
C
To activate the function, change the settings of parameter
FC.En
E1 E2 E3 E4 E5
ENCODER
12Vdc
M1

5.9 - FLASHING LIGHT

CITY1-EVO provides for a 230V - 40W (120V – 40W for 120V
model) flashing light equipped with intermittence inside.
Connect flashing light cables to terminals H1 and H2 of the
control unit.
H1 H2 H3 H4 H5 H6 H7 H8
230V - 40W
Z1 Z2 Z3 Z4 Z5 Z6

Publicidad

Tabla de contenido
loading

Tabla de contenido