V2 CITY1-EVO Manual De Usuario página 58

Cuadro de maniobras digital para cancelas batientes y puertas correderas
Ocultar thumbs Ver también para CITY1-EVO:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PARAMETER
VALUE
Co.tE
no
rESi
Foto
FC.En
no
rALL
StoP
EnCo
no
1 - 4
i.Adi
no
Si
SCAn
DESCRIPTION
Test of the safety edges
This menu allows setting the method of control of the safety edges
working
Test disabled
Test enabled for conductive rubber safety edges
Test enabled for optical safety edges
Limit switch inputs
Limit switch inputs are disabled
Inputs enabled: the gate starts the slowdown phase near the limit switches
Inputs enabled: the gate stops near the limit switches
Enabling encoder and adjustment of sensitivity
NOTE: The terminals dedicated to the encoder are the same of the limit
switches; if the inputs of the two motors limit switches are enabled
FC.En
StoP
(parameter
=
/
Input disabled
This value indicates the sensitivity with which the unit interprets a
slowdown of the motor in the presence of an obstacle
(1 = less sensitive / 4 = more sensitive).
Enabling the ADI device
This menu makes it possible to enable operation of the device connected
to the ADI 2.0 connector.
If an ADI normal (CL1+, WES-ADI, LUX2+) device is connected, select the
Si
value to enable the interface and proceed with programming of the
device.
If one or more ADI 2.0 devices are connected, it is necessary to select
SCAn
value so that the unit detects the devices.
During scanning, the display shows the number of detected devices.
Once scanning is completed, the display shows
ESC
- select
to exit from the menu without programming the devices;
- press the UP or DOWN key to display the list of devices; hence
select the device to be programmed and press MENU to enter the
programming menu of the selected device.
NOTE: The ADI devices programming menu is different for each device.
Refer to the manual of the device.
ATTENTION: Scanning must be performed only when new ADI 2.0
devices are connected. To repeat programming of a device or to program
Si
another, simply select value
Exiting the ADI device configuration menu returns to the
Interface disabled
Interface enabled: access to the programming menu of the ADI device, or
to the connected ADI 2.0 list of devices.
Si
NOTE: If the
option is selected, but no device is connected, the display
will show a series of dotted lines (
Learning about the connected ADI 2.0 devices
NOTE: This option is available only if on the ADI connector is inserted an
ADI 2.0 module.
NOTE: Every time that an ADI device is added or removed, it is necessary
to repeat the scanning procedure to update the unit.
rALL
) the encoder is always disabled.
ESC
:
to access the list of devices.
i.Adi
- - - -
).
- 56 -
AntE SCor
no
no
no
StoP
no
no
no
no
option
MEMO

Publicidad

Tabla de contenido
loading

Tabla de contenido