Design Guide - Standard Installation
CLEARANCES
23-7/8 "
Minimum
to Wall
130° Door Swing
130°
These units are equipped with a 3-position door stop.
The factory set 115° door swing can be adjusted to
90° or 130° if clearance to adjacent cabinets or walls is
restricted. Order WX14X99 door stop for precise set-
tings between 90° and 130°.
When Installed into a corner:
Allow 23-7/8" (60.64 cm) for a full 130° door swing.
Allow 15" (38.1cm) for pan removal. Allow 4-9/16"
(11.59 cm) min. clearance when door swing is adjusted
to a 90° opening for pan access, but pan removal is
restricted.
23-7/8"
Min. to
130° Door
Wall
Swing
Clearances for Multiple Single Door Installations
In a side-by-side installation of a left and right door
swing product, a 1" (2.54 cm) clearance between the
units is required. Order a ZKBSN720NSS Unification Kit
for an integrated appearance on 2 stainless steel models
installed side-by-side. Order a ZKBFN720NII Unification
Kit for an integrated appearance on 2 custom panel
models installed side-by-side.
INSTALLATION
ZKBSN720NSS, ZKBFN720NII Unification Kit
• If you are installing two units, side by side, the installa-
tion space must be 71-1/2" (181.61 cm) wide.
NOTE: Additional cutout width may be required when
side panels are used. Add side panel thickness to the fin-
ished cutout to calculate rough-in width.
• The water and electrical locations for each product
must be located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
"
4-9/16
Min. Distance to Wall
90º Door Swing
"
36-1/2
90°
1"
23-7/8"
Min. to
130° Door
Wall
Swing
2"
Clearances for two products installed side-by-side
with the same (left or right) door swing
Allow 2" (5.08 cm) minimum clearance between the
products to prevent door swing interference. Order
the WX14X99 adjustable door stop to reduce the
factory set 115° door swing. Allow 16-7/8" (42.86 cm)
minimum to a wall to achieve full drawer extension
and pan removal.
NOTE: ZKBSN720NSS and ZKBFN720NII Unification
Kit will NOT fit this installation.
Clearances for two products installed side-by-side
with right and left side hinges together Allow 5" (12.7
cm) minimum between the two products to prevent one
door from striking the other. Use the WX14X99 adjust-
able door stop to reduce the factory set 115° door swing
and to allow pan removal.
NOTE: ZKBSN720NSS and ZKBFN720NII Unification Kit
will NOT fit this installation.