Function
The control unit START S7lT is for automatic doors, too. now we can see the correct installation. First of all
there are two functions: STAndARd function and AUToMATIC dooR function.
STANDARD FUNCTION
Encoder
The control unit opens and closes with an addi-
tonal time of 2 sec to support the latch.
Obstacle detection
The intervention of the obstacle detection is
consider as limit switch
The control unit START-S7lT has two versions available. Make as follow to program the different versions:
1
Turn off the control unit, take out the 230V tension
2
Connect the control unit START-S7lT after a while again
3
LED1 remains lit for 5 seconds
4
Press and release the button P1 in 5 seconds
5
Count the fl ash of the LED L1
1 fl ash: it has been activated the STANDARD VERSION (Default)
6
2 fl ashes: it has been activated the AUTOMATIC DOOR VERSION
If you want to change the version, go back to point no. 4
7
otherwise choose from the list P1.
(Default)
-13-
AUTOMATIC DOOR FUNCTION
Encoder
The control panel stops the motor in the position set
during learning.
Obstacle detection
during the opening phase, the central reverses the
motor direction and executes a closure at low speed.
during the closing phase of the central reverses the
motor direction. whether oPenS CloSeS during the
slowdown that the intervention is considered as limit
switches.
operating guide
LED1
P1
LED1