Description Of The Electrical Connections; Checking Connections - EB TECHNOLOGY Nologo START-S7LT Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

START-S7lT
4.3

Description of the electrical connections

12/24 Vac/dc
Motor
- 12/24 Vdc
+ 12/24 Vdc
i.c. lamp
contact for elec.
lock / signal light
Stop 11
Photo Cl 12
olS 13
ClS 14
Start 15
Close 16
Common 17
+ Antena 18
+ 5 Vdc 19
Sgn encoder 20
- 5 Vdc 21
4.4

Checking connections

The LED L1 indicate the correct logic of the control board. It fl ashes each second and it indicates
that the micro-chip is activated and it is waiting for a command.
when the control board is powered, the led are lit on when the input is a closed contact.
normally the red led STOP - PHOTO - OLS - CLS are lit on
normally the green led in in the START - CLOSE are switched off
1
Input for low tension: set up the JUMPeR J12
2
3
output for the connection of the MoToR
4
5
output for the connection of the accessories: Absorption max 1.6 A
6
7
Isolated contact for lAMP
8
9
Isolated contact for eleC. loCK or SIGnAl lIGHT
10
Ingresso SToP
Input photocell PHoTo: operating only when closing
Input for open limit Switch
Input for Close limit Switch
Input for START command: set up dIP 1 and dIP2
Input CloSe command
Common, services and securities
Positive pole antena
Power supply of the encoder
encoder signal
Power supply of the encoder
STOP
PHOTO
OLS
CLS
START
-7-
!
We remind you that in
case some inputs are not
used, (STOP, FOTO) you
need to be deactivated
with DIPB as shown in the
Par 5.2
CLOSE
operating guide

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido