Turn on and programm
When the control unit will turn on again, if everything will be connected in the right way, led L1 (red) should flash
while the led of inputs STOP - PHOTO - OLS - CLS - ALT - SAFETy EDGE should turned off (if the gate is
closed olS is turned off). The led START and Ped should turned off. when you turned off the control unit, the
gate is opening it means that the control card has been previously turned off while it was open .
ON
1
2
3
4
5
6
7
8
9
10
7.1
Memorization of the working time
Here you can memorize the working time.You need to use the START command. Those commands can be
used with a device connected to the terminal board 15-17 or from a memorized remote control (see MeMoRI-
ZATIon oF THe ReMoTe ConTRol)
This operation is possible only when the gate is closed. Start from the initial condi-
tion of the control unit.
Put DIP9 in ON before powering the control unit.
It is necessary to set up the mechanical closing limit switches (when closing and opening)
If you had to set up the working time. Turn off the control card, close the
gate, put DIP9 in ON and give power supply to the control card.
Put in ON the DIP9 and you can set up
- working time and pause time
- position of the slow down
- activation or deactivation of the lamp in pause time