Function
10
Parameter access
L1:
Level 1 access - only the first 10 parameters can be accessed
L2:
Level 2 access - All parameters from 01 to 60 can be accessed
L3:
Level 3 access - All parameters from 01 to 95 can be accessed
Loc: Used to lock a security code in the drive. See section 5.6 Security codes on
page 64 for further details.
6.2
Parameter descriptions - Level 2
No
Function
11
Start/Stop logic select
Pr 11
0
Enable
1
Not Stop
2
Enable
3
Not Stop
4
Not Stop
5
User programmable
6
User Programmable User Programmable User Programmable
A change to Pr 11 is set by pressing the
NOTE
The drive must be disabled, stopped or tripped for a change to take place. If Pr 11 is
changed while the drive is running, when the
parameter edit mode, Pr 11 will change back to its previous value.
No
Function
12
Brake controller enable
diS: Mechanical brake software disabled
rEL: Mechanical brake software enabled. Brake control via relay T5 & T6. The digital
output on terminal B3 is automatically programmed as a drive healthy output.
d IO: Mechanical brake software enabled. Brake control via digital output B3. The relay
outputs on terminals T5 and T6 are automatically programmed as a drive healthy
output.
USEr:Mechanical brake software enabled. Brake control to be programmed by user.
The relay and digital output are not programmed. The user should programme the
brake control to either the digital output or relay. The output not programmed to
the brake control can be programmed to indicate the required signal. (See
Digidrive SK Advanced User Guide.)
A change to Pr 12 is set by pressing the
NOTE
The drive must be disabled, stopped or tripped for a change to take place. If Pr 12 is
changed while the drive is running, when the
parameter edit mode, Pr 12 will change back to its previous value.
See Pr 46 to Pr 51 on page 77.
Great care should be taken when implementing a brake control set-up, as this may cause
a safety issue depending on the application, e.g. crane. If in doubt, contact the supplier
of the drive for further information.
WARNING
Digidrive SK Getting Started Guide
Issue Number: a
English
Terminal B4
Terminal B5
Run Forward
Run Forward
Run
Run
Run
Run Forward
Deutsch
Italiano
Range
L1, L2, L3, Loc
Range
0 to 6
Terminal B6
Run Reverse
Run Reverse
Forward / Reverse
Forward / Reverse
Jog
Run Reverse
MODE key on exit from parameter edit mode.
M
MODE key is pressed on exit from
M
Range
diS, rEL, d IO, USEr
MODE key on exit from parameter edit mode.
M
MODE key is pressed on exit from
M
Español
Defaults
Type
L1
RW
Defaults
Type
EUR: 0, USA: 4
RW
Latching
No
Yes
No
Yes
Yes
No
User Programmable
Defaults
Type
diS
RW
71