Trip resistance: 3kΩ
Reset resistance 1k8
If Pr 34 is set to th so that terminal B7 is used as a motor thermistor, the functionality of
NOTE
terminal B7 as set-up with Pr 05, drive configuration, will be disabled.
No
Function
35
Digital output control (terminal B3)
n=0:
At zero speed
At.SP: At speed
Lo.SP: At minimum speed
hEAL: Drive healthy
Act:
Drive active
ALAr: General drive alarm
I.Lt:
Current limit active
At.Ld: At 100% load
USEr: User programmable
This parameter is automatically changed by the setting of Pr 12. When Pr 12
NOTE
automatically controls the setting of this parameter, this parameter cannot be changed.
A change to this parameter is only implemented if the drive is disabled, stopped or
NOTE
tripped and the
See the Digidrive SK Advanced User Guide.
No
Function
36
Analog output control (terminal B1)
Fr:
Voltage proportional to motor speed
Ld:
Voltage proportional to motor load
A:
Voltage proportional to output current
Por:
Voltage proportional to output power
USEr: User programmable
A change to this parameter is only implemented if the drive is disabled, stopped or
NOTE
tripped and the
See the Digidrive SK Advanced User Guide.
No
Function
37
Maximum switching frequency
3:
3kHz
6:
6kHz
12:
12kHz
18:
18kHz
See the Digidrive SK Advanced User Guide for drive derating data.
No
Function
38
Autotune
0: No autotune
1: Non-rotating static autotune
2: Rotating autotune
Digidrive SK Getting Started Guide
Issue Number: a
English
Deutsch
n=0, At.SP, Lo.SP, hEAL,
Act, ALAr, I.Lt, At.Ld, USEr
STOP/RESET key is pressed for 1s.
Fr, Ld, A, Por, USEr
STOP/RESET key is pressed for 1s.
Italiano
Range
Range
Range
3, 6, 12, 18 kHz
Range
0 to 2
Español
Defaults
Type
n=0
RW
Defaults
Type
Fr
RW
Defaults
Type
3
RW
Defaults
Type
0
RW