7) Additional information

Programming, personalisation and how to look for and deal with faults on the ROBUS350 will be dealt with in this chapter.
7.1) Programming keys
The ROBUS350 control unit feature three keys that can be used to
command the control unit both during tests and programming.
Open
The "OPEN" key enables the user to control the opening of the gate or move
the programming point upwards.
Stop
The "STOP" key enables the user to stop the manoeuvre. If pressed down for
Set
more than 5 seconds it enables the user to enter programming.
Close
The "CLOSE" key enables the user to control the closing of the gate or move
the programming point downwards.

7.2) Programming

A number of programmable functions are available on the
ROBUS350 control unit. The functions are adjusted using 3 keys set
on the control unit: [▲] [Set] [▼] and are used by means of 6
LEDs: L1....L6
The programmable functions available on ROBUS 350 are set out on
2 levels:
7.2.1) Level one functions (ON-OFF functions).
Table 12: list of programmable functions: Level one
Led
Function
L1
Automatic Closing
L2
Close After Photo
L3
Always Close
L4
Stand-By
L5
Peak
L6
Pre-flashing
During the normal functioning of the ROBUS350, LEDs L1....L6 will either be on or off depending on the state of the function they
represent. For example, L1 will be on if the "Automatic Closing" function is active.
12
Description
This function causes the gate to close automatically after the programmed time has lapsed. The factory set
Pause Time is 30 seconds, but can be changed to 5, 15, 30, 45, 60 or 80 seconds. If the function is inactive,
functioning will be "semi-automatic".
This function means it is possible to close the gate 5 seconds after the photocells have disengaged, even if the
pause time is set to a higher value. Functioning varies according to whether "Automatic Closing" is active or inactive.
When "Automatic Closing" is active, the opening manoeuvre stops immediately after the photocells have
disengaged. After 5 seconds, the gate will begin to close.
When "Automatic Closing" is inactive the opening manoeuvre will not be interrupted but, when the photocell
disengages, this will cause a closing manoeuvre after 5 seconds. If the function is inactive, the pause time will be the
one which has been programmed.
The "Always Close" function will trigger, and the gate will close if an open gate is detected when the
power supply returns. A light will flash for 5 seconds before the manoeuvre starts for reasons of safety. If
the function is inactive when the power supply returns, the gate will remain still.
This function enables the user to lower consumption to a very minimum. It is particularly useful in cases
when the buffer battery is being used. If this function is active, the control unit will switch the BLUEBUS
output (and consequently the devices) and all the LEDs off one minute after the end of the manoeuvre.
The only LED which will remain on is the BLUEBUS LED which will simply flash more slowly. When a
command arrives, the control unit will reset to complete functioning. If this function is inactive, there will
be no reduction in the consumption.
If this function is activated, the gradual acceleration at the beginning of each manoeuvre will be
disconnected. It enables the peak thrust and is useful whenever static friction is high, e.g. if snow or ice
are blocking the leaf. If the thrust is inactive, the manoeuvre will start with a gradual acceleration.
With the pre-flashing function, a 3 second pause is added between the flashing light switching on and
the beginning of the manoeuvre in order to warn the user, in advance, of a potentially dangerous
situation. If pre-flashing is inactive, the flashing light will switch on when the manoeuvre starts.
21
Level one: the functions can be adjusted in modes ON-OFF (acti-
ve or inactive). In this case, each of the LEDs L1....L6 indicates a
function. If the LED is on, the function is active, if off the function is
inactive. See Table 12
Level two: the parameters can be adjusted on a scale of values
(from 1 to 6). In this case, each of the LEDs L1....L6 indicates the
value set (there are 6 possible settings). Please refer to Table 14.