Remote" Memorization; Deleting The Radio Transmitters; Declaration Of Conformity Of The Radio Receiver; Testing And Commissioning - Nice Robus 350 Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 90

4.7.3) "Remote" memorization

A new radio transmitter can be memorized without directly operat-
ing the keys on the receiver. You need to have a pre-memorized
operational radio transmitter. The "new" radio transmitter will inherit
the characteristics of the old one, i.e. if the old radio transmitter was
memorized in Mode 1, the new one will also be memorized in Mode
1. In this case, during the memorization stage you can press any key
on the two transmitters. If, on the other hand, the old transmitter was
memorized in Mode II, the new one will also be memorized in Mode
II: you must press the key on the old transmitter which corresponds
to the desired command, and the key on the new transmitter to
which you wish to associate that command
Holding the two transmitters, position yourself within the operating range of the automation and perform the following operations:
Table 10: for the "Remote" memorization of a transmitter
1.
Press the key on the new radio transmitter and hold it down for at least 5 s, then release it.
2.
Press key on the previously memorized transmitter slowly 3 times.
3.
Press the key on the new radio transmitter once slowly.
At this point the new radio transmitter will be recognized by the receiver and will assume the characteristics of the previously memorized
one. If there are other transmitters to be memorized, repeat all the steps above for each new transmitter.

4.7.4) Deleting the Radio Transmitters

Table 11: to delete all the radio transmitters
1.
Press the key on the receiver and hold it down
2.
Wait until the LED lights up, then wait until it goes off, then wait until it has flashed 3 times
3.
Release the key precisely upon the third flash.
4.
If the procedure is successful, after a few moments the LED will flash 5 times.

4.7.5) Declaration of conformity of the radio receiver

Declaration of conformity
N°: 151/SMXI
Nice S.p.a., Via Pezza Alta 13, 31046 Rustignè di Oderzo (TV) Italy
NICE S.p.a. declares that radio receiver models SMXI, SMXIS and the relative FLO2R-S and SM2 transmitters conform to the essential requi-
sites specified in Directive R&TTE 1999/5/CE, for the use the devices have been manufactured for. Manufactured in Class 1, Sub-class 20.
Fabbricato in Classe 1, Sub-classe 20
Date 19th March 2004

5) Testing and commissioning

This is the most important stage in the automation system installa-
tion procedure in order to ensure the maximum safety levels. Testing
can also be adopted as a method of periodically checking that all the
various devices in the system are functioning correctly.
!
Testing of the entire system must be performed by
qualified and experienced personnel who must establish
which tests to conduct on the basis of the risks involved,
and verify the compliance of the system with applicable
regulations, legislation and standards, in particular with
all the provisions of EN standard 12445 which establishes
the test methods for automation systems for gates
10
Rev03
!
remote memorisation can occur in all those receivers
which are within range of the capacity of the transmitter.
Therefore, only the one which is actually involved in the
operation must be powered.
Example
5s
1s
1s
1s
1s
Example
x3
x5
Managing Director
Lauro Buoro
I

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Robus350

Tabla de contenido