KwikDial Components

1 - LCD Display
2 - Control Dial - Select controller programming and
operating functions.
Control Dial Positions:
Auto
- Dial position for automatic operation.
Date / Time
Water Days
1
week for automatic watering.
Odd/Even
watering day (date) schedule.
Interval
schedule.
Start Times
watering program.
- To set station run time duration.
Stations
Manual Station(s)
manual operation.
Manual Programs
programs for manual operation.
Special Functions
functions.
Test
- To run a test program to check station
operation.
OFF
- Turns off and prevents all station operation.
3 - Sensor Switch - Active/Bypass switch to control
operation of an optional rain sensor.
4 - Sensor Connection Terminals
5A- Plug-in Transformer Connection Terminals
2
(indoor models only).
- To set the current date and time.
- To select individual days of the
2
3
- To set an Odd or Even
- To set a Day Interval watering
- To set start times(s) for automatic
- To select station(s) for
- To select watering
- To select optional controller
5B- Power Connection Wires (outdoor domestic and
Australian models only)
5C- Power Connection Terminals (outdoor international
models only).
6 -
and
Buttons - Press to increase or decrease
display number values and various manual functions.
7 -
Button - Press to select program A, B or C.
8 -
Button - Press to advance to next portion of
program information or next station when operating.
9 - Station Terminals - Connection terminals for valve
control wires, master valve or pump start relay wires.
10 - Plug-in Transformer (indoor models only) - Supplies
24 V a.c. power to the controller from a grounded
wall plug outlet. (Domestic model shown.)
11 -
Symbol - Displayed when setting an automatic
watering program start time.
12 -
Symbol - Displayed when watering is on or set.
The
symbol indicates no watering is set.
13 - Station Numbers - Displayed when setting program
start time(s) and while a station is running.
14 -
Symbol - Displayed 30 seconds when charging
back-up power to retain program memory.
15 - Today/
Symbol - Displayed when setting a Day
Interval schedule. The
language other than English is selected.
16 -
Symbol - Displayed when setting the station run
time duration.
17 - % Symbol - Displayed when a Watering Budget run
time duration adjustment is in use.
18 - Main Display - Shows various time values and
controller information.
19 - A B C - Program letter identifiers displayed during
programming and operation.
20 - Reset Contacts - Momentarily connect the contacts
with a metal conductor such as the tip of a flat
screwdriver to reset all programming parameters to
the factory default settings.
symbol is shown when a