Read this Manual 
This manual provides informa on on the installa on, opera on, and maintenance of the water heater.  For proper 
opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.   
Instruc ons on proper installa on and regular maintenance of the water heater should be followed to properly 
operate the water heater and to maintain the warranty. 
Read all of the instruc ons thoroughly before installing or opera ng this water heater. 
WARNING
—  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 
appliance. 
—  WHAT TO DO IF YOU SMELL GAS 
• Do not try to light any appliance. 
• Do not touch any electrical switch; do not use any phone in your building. 
• Immediately call your gas supplier from a neighbor's phone.  Follow the gas supplier's instruc ons. 
• If you cannot reach your gas supplier, call the fire department. 
—  Installa on and service must be performed by a licensed professional. 
This en re manual must be le  for the consumer.  The consumer must read and  
refer to this manual for proper opera on and to maintain the water heater. 
J‐SN180W 
J‐SP180W 
J‐SN199W 
J‐SP199W 
ANS Z21.10.3  ● CSA 4.3 
If the informa on in these instruc ons is not followed exactly, a fire or explosion 
may result causing property damage, personal injury or death. 
Direct Vent Tankless Water Heater 
Installa on and Opera on Manual 
U307‐1021 

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Jacuzzi J-SN180F

  • Página 1: Installa On Of Temperature Controller

    Direct Vent Tankless Water Heater  Installa on and Opera on Manual  Signature Tankless Water Heaters  J‐SN180F  J‐SN180W  J‐SP180F  J‐SP180W  J‐SN199F  J‐SN199W  J‐SP199F  J‐SP199W  ANS Z21.10.3  ● CSA 4.3  Read this Manual  This manual provides informa on on the installa on, opera on, and maintenance of the water heater.  For proper  opera on and safety, it is important to follow the instruc ons and adhere to the safety precau ons.    Instruc ons on proper installa on and regular maintenance of the water heater should be followed to properly  operate the water heater and to maintain the warranty.  Read all of the instruc ons thoroughly before installing or opera ng this water heater.  If the informa on in these instruc ons is not followed exactly, a fire or explosion  WARNING may result causing property damage, personal injury or death.  —  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other  appliance.  —  WHAT TO DO IF YOU SMELL GAS  •...
  • Página 2: Tabla De Contenido

    Manual Draining of the Water Heater  ..... 39    Adjust for High Al tude ........ 20  State Regula ons ........... 40    Adjust for Vent Length  ........ 20  Replacement Parts .......... 41    Checklist for Gas and Electricity ...... 20  Consumer Warranty  .......... 42  Jacuzzi some mes shares customer contact informa on with businesses that we believe provide products or  services that may be useful to you.  By providing this informa on, you agree that we can share your contact  informa on for this purpose.  If you prefer not to have your informa on shared with these businesses, please  contact customer service and ask not to have your informa on shared.  We will however, con nue to contact  you with informa on relevant to the product(s) you registered and/or you account with us.  Important Safety Informa on  Safety Defini ons  This is the safety alert symbol.  This symbol alerts you to poten al hazards that can kill or hurt you      and others.
  • Página 3: Safety Behaviors And Prac Ces For The Consumer And Installer

    • a licensed professional.  Force or a empted repair  Should overhea ng occur or the gas supply fail to  may result in a fire or explosion.  shut off, turn off the manual gas control valve to  the appliance.  • Keep the area around the appliance clear and free  • from combus ble materials, gasoline, and other  Do not use an extension cord or an adapter plug  flammable vapors and liquids.  with this appliance.  CAUTION • • BURN HAZARD.  Hot exhaust and vent may cause  Hot water outlet pipes leaving the unit can be hot  serious burns.  Keep back from water heater unit.   to touch.  In residen al applica ons, insula on  Keep small children and animals away from unit.  must be used for hot water pipes below 36” due to  burn risk to children.  California law requires this no ce to be provided:  California Proposi on 65 lists chemical substances known to the state to cause cancer, birth defects, death,  serious illness or other reproduc ve harm.  This product may contain such substances, be their origin from fuel  combus on (gas, oil) or components of the product itself.    Jacuzzi Signature Water Heaters J‐S180/J‐S199  3 ...
  • Página 4: Installa On Instruc Ons

    The appliance and its appliance main gas valve    Connect Electricity ...........  2 0  must be disconnected from the gas supply piping    Adjust for High Al tude ........  2 0  system during any pressure tes ng of that system    Adjust for Vent Length  ........  2 0  at test pressures in excess of 1/2 psi (3.5 kPa)  (13.84 in W.C.).    Checklist for Gas and Electricity  .......  2 0    Installa on of Temperature Controller  ....  2 1    Final Checklist ..........  2 2  4  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 5: Prepare For Installa On

    Approved ven ng  compound  • Pressure relief valve  Materials that may be needed  • • Heat tape  5/8” ID PVC flexible  tubing  • Pipe insula on  • 2 conductor 22 AWG  • Electrical wire and  wire for controller  conduit per local code  • Single gang electrical  • Concrete wall anchors  box  • Op onal pipe cover   • Wire nuts  • Op onal temperature  • Unions, drain valves,  controller  isola on valves    Jacuzzi Signature Water Heaters J‐S180/J‐S199  5 ...
  • Página 6: Determine Installa On Loca On

    Solids) *  • Chemicals that are corrosive in nature should not  be stored or used near the water heater.  Zinc *  Up to 5 mg / L    Outdoor/External Water Heaters and Vent  * Source: Part 143 Na onal Secondary Drinking Water  Termina ons of Indoor/Internal Water Heaters  Regula ons  • Install the water heater as far away as possible  If you live in an area that is known to have hard water  from exhaust vent hoods.  or that causes scale build‐up you must treat your  • Install as far away as possible from air inlet  water and/or flush the heat exchanger regularly.  vents.  Corrosive fumes may be released through  these vents when air is not being brought in  When scale build‐up in the heat exchanger begins to  through them.  affect the performance of the water heater, a  • diagnos c code “LC#” will display.  Flush the heat  Chemicals that are corrosive in nature should not  exchanger to prevent damage to it.  Scale build up is  be stored or used near the water heater or vent  caused by hard water set at a high temperature.    termina on.  Damage and repair due to corrosive compounds in  the air is not covered by warranty.  6  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 7 I  Clearance to service regulator vent outlet  *  Clearance to nonmechanical air supply inlet to building or the  J  12 inches (30 cm)  combus on air inlet to any other appliance  3 feet (91 cm) above if within 10  K  Clearance to a mechanical air supply inlet  feet (3 m) horizontally  Clearance above paved sidewalk or paved driveway located on public  L  *  property  M  Clearance under veranda, porch, deck, or balcony   *  ∗ [1]  A vent shall not terminate directly above a sidewalk or paved driveway  For clearances not specified in ANSI Z223.1/NFPA 54, clearances are in  that is located between two single family dwellings and serves both  accordance with local installa on codes and the requirements of the gas  dwellings.  supplier.  [2]  Permi ed only if veranda, porch, deck, or balcony is fully open on a    Clearance to opposite wall is 24 inches (60 cm).  minimum of two sides beneath the floor.    Jacuzzi Signature Water Heaters J‐S180/J‐S199  7 ...
  • Página 8 (1.52 m) ver cally  60" between terminals  • Install vent termina on such that exhaust and  rising moisture will not collect under  eaves.  Discolora on to the exterior of the  building could occur if installed too close.  • Do not install the vent termina on too close  under the soffit where it could present  recircula on of exhaust gases back into the  combus on air intake part of the termina on.  (0.61 m) to wall or parapet  24"     36" 12" (0.30 m ) to  an inside  12" corner  (0.30 m) between   terminals at same  12" level  (0.30 m) between   terminals at same  level  INSIDE CORNER 8  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 9   Addi onal clearances (Outdoor Models)  Check on whether local codes supersede these clearances.  • Avoid termina on loca ons near a dryer vent.  • Avoid termina on loca ons near commercial  cooking exhaust.  (0.91 m) to ven lated or unven lated soffit or eve vent;  36" or to a deck or porch  12" 2" (50 mm) between terminals at same level  (0.30 m) to an  inside corner  60" (1.52 m) ver cally  between terminals    Jacuzzi Signature Water Heaters J‐S180/J‐S199  9 ...
  • Página 10 0 (zero)  Front (Panel)  24 (610)  0 (zero)  Front of Heater  6 (152)  6 (152)  Front (Exhaust)  24 (610)  24 (610)  Sides of Heater  2 (51)  1/2 (13)  Sides of Heater  6 (152)  1/8 (3.2)  Ground/Bo om  12 (305)  12 (305)  Ground/Bo om  12 (305)  2 (51)  Vent  0 (zero)  0 (zero)  * 0 inches from vent components and condensate  The clearance for servicing is 24 inches in front of the  drain line.  water heater.  The clearance for servicing is 24 inches in front of the    water heater.  For closet installa on, clearance is 6 inches (152 mm  from the front.    10  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 11 3 If the length is greater than 9   (2.7 m) then move  heater is disabled due to a diagnos c code.    switch No. 1 (SW1) to OFF.  The freeze protec on features will not prevent the  4 Move switch No. 1 (SW1) to OFF.  external piping from freezing.  It is recommended that  Example:  If you have one elbow then your maximum  hot and cold water pipes are insulated.  Pipe cover  vent length is 35 feet (10.7 m).  If your  enclosures may be packed with insula on for added  actual length is greater than 15   (4.6 m)  freeze protec on.  then move switch no. 1 (SW1) to OFF.  In the event of a power failure at temperatures below  freezing the water heater should be drained of all  water to prevent freezing damage.  NOTICE    If you have a longer vent length (see above), switch  No. 1 is required to be in the  OFF posi on.  This  ensures the water heater will run properly.  Blocked  flue diagnos c codes and shutdowns may result if  switch No. 1 is not in the correct posi on.     Jacuzzi Signature Water Heaters J‐S180/J‐S199  11 ...
  • Página 12: Checklist To Determine Installa On Loca On

    Refer to the weight of the water heater in the  □  Specifica ons sec on.  The installa on must conform with local codes or,  in the absence of local codes, with the Na onal NOTE: The water heater should be installed in an  Fuel Gas Code, ANSI Z223.1/NFPA 54.  If installed  upright posi on.  Do not install upside down or on its  in a manufactured home, the installa on must  side.  conform with the Manufactured Home Construc on and Safety Standard, Title 24 CFR, Part 3280.  Remove the Front Panel  Slide the plas c trim pieces on each side of the water  heater to expose the screws.  Remove the 4 screws and pull off the front panel.  12  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 13: Installa On Of Ven Ng (Indoor Models)

      Installa on of Ven ng (Indoor Models)  Install the correct ven ng for your model according to the ven ng manufacturer’s instruc ons and the guide‐ lines below.  Refer to the manufacturer’s technical literature for specific part numbers and instruc ons.    Listed and Tested Vent  Manufacturer  Telephone  Fax  Contact  Products  Ubbink  Rolux Vent System   800‐621‐9419  678‐829‐1666  www.jacuzzi.com/tankless  Heat‐Fab  Saf‐T Vent SC system  custsvc@heat‐fab.com,  800‐772‐0739  413‐863‐4803  www.hea ab.com  Metal‐Fab  Corr/Guard Vent/Air Intake  info@mtlfab.com,  800‐835‐2830  316‐943‐2717  System  www.metal‐fabinc.com    Ven ng Guidelines     ...
  • Página 14 (condensate collector must be used in all installa ons)  Condensate  Condensate  Trap  Trap  3 in (75 mm)  minimum  3 in (75 mm)  3 in (75 mm)  minimum  minimum  To adjust the condensate collector posi on or to  replace the female vent top with a male vent top:  Bracket  1.  Loosen the 4 screws at the rear bracket   Condensate Collector  2.  Slide the bracket away from the female vent top.  3.  Remove the 4 screws a aching the female vent top  to the water heater.  4.  Li  up the female vent top and reposi on as desired  (or replace with a male vent top).  5.  Install the 4 screws at the vent top and  ghten the 4  screws at the bracket.  Secure the first vent component to the water heater  Securing Screw  with one self‐tapping screw at the hole located above  the condensate collector.  14  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 15: Condensate (Indoor Models)

    □  Verify that the vent pipe has a downward slope or  • The end of the condensate drain pipe should be  grade to the outside of 1/4 inch per foot (1.2°)   open to the atmosphere.  The end should not be  OR if the vent pipe is sloped toward the water  under water or other substances.  heater (as some local codes require), that a  • To minimize freezing of the condensate, run the  condensate collector is installed to allow  condensate drain line through an interior wall or  condensa on to drain away from the water  between insula on and an interior wall.  heater to a proper drain source.  □  • The condensate collector should be used for all  Verify that condensate will not be allowed to  hydronic hea ng applica ons.  drain back into the water heater.  □  Verify that the vent system does not exceed the  maximum length for the number of elbows used.     Jacuzzi Signature Water Heaters J‐S180/J‐S199  15 ...
  • Página 16: Installa On Of Plumbing

    DO NOT  pressure relief valve for this appliance.  However,  • Do not plug the relief valve and do not install any  local codes may require a combina on  reducing fi ngs or other restric ons in the relief  temperature and pressure relief valve.  line.  The relief line should allow for complete  Isola on Valves    drainage of the valve and the line. Jacuzzi recommends installa on of isola on valves on  • Do not place any other type valve or shut off  the cold and hot water lines.  Isola on valves provide  device between the relief valve and the water  the ability to isolate the water heater from the    heater. structure’s plumbing and allow quick access to flush  MUST DO  the heat exchanger.    • The relief valve must comply with the standard for  Relief Valves and Automa c Gas Shutoff Devices for Hot Water Supply Systems ANSI Z21.22 and /or the ...
  • Página 17 It is the responsibility of the contractor/engineer to ensure installation is in Check Valve Boiler Drain Valve accordance with all local building codes. Confer with local building Pressure Relief Valve officials before installation. Solenoid Valve   Jacuzzi Signature Water Heaters J‐S180/J‐S199  17 ...
  • Página 18: Checklist For Plumbing

    • Before placing the appliance in opera on all joints  side of the water heater for BTU input.  including the heater must be checked for gas  □  ghtness by means of leak detector solu on, soap  Clean the inlet water filter by closing the cold and  and water, or an equivalent nonflammable  hot water inlet isola on (shut‐off) valves.  (Turn  solu on, as applicable.  (Since some leak test  off the water supply if a shut‐off valve is not  solu ons, including soap and water, may cause  installed.)  Put a bucket under the filter at the  corrosion or stress cracking, the piping shall be  bo om of the water heater to catch any water  rinsed with water a er tes ng, unless it has been  that is contained inside the unit.  Unscrew the  determined that the leak test solu on is non‐ water filter.  Rinse the filter to remove any debris.   corrosive.)  Install the filter and open the isola on valves.  • Use approved connectors to connect the unit to  the gas line.  Purge the gas line of any debris  before connec on to the water heater.  18  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 19 The hea ng value of natural gas for your loca on is  1000 BTU/FT .  The gas input of the J‐SN199F is  40  137  287  541  1110  199,000 BTU/HR.  Addi onal appliances at the loca‐ 50  122  255  480  985  on require 65,000 BTU/hr.  Therefore the cubic feet  per hour = (199,000 + 65,000) / 1000 = 264 FT /HR.  If  60  110  231  434  892  the pipe length is 10 feet then the 3/4 inch pipe size is  80  101  212  400  821  capable of supplying 264 FT /HR of natural gas.  100  94  197  372  763    Jacuzzi Signature Water Heaters J‐S180/J‐S199  19 ...
  • Página 20: Connect Electricity

    On outdoor models, a disconnect switch must be    vent length”. provided and installed for the incoming 120 VAC  power.  It should be a type that is suitable for outdoor  Checklist for Gas and Electricity  use.  Check the Na onal Electrical Code, ANSI/NFPA  70 and your local codes for a proper switch type to  □  A manual gas control valve is placed in the gas  use in your area.  line to the water heater.  The wiring diagram is located on the Technical Sheet  □  a ached to the inside of the front cover.  Check the gas lines and connec ons for leaks.  □  Confirm that the gas inlet pressure is within  limits.  □  Confirm that the water heater is rated for the gas  type supplied.  □  Confirm that the electricity is supplied from 120  VAC, 60 Hz power source and is in a properly  grounded circuit.  □  An extension cord or an adapter plug has not  been used with the water heater.  □  For indoor models, verify that switch No. 1 in the  SW1 DIP switch (tan switches) has been adjusted  for vent length if necessary.  Refer to the sec on  on Maximum Vent Length.  20  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 21: Installa On Of Temperature Controller

    9.  Secure the controller cable using the clamp  Cable Lengths and Sizes  provided.  The cable for the temperature controller should be a  10.  Replace plas c cover over PCB and then replace  non‐polarized two‐core cable with a minimum gauge  the cover of the water heater.  of 22 AWG.  The maximum cable length from each  controller to the water heater depends on the total  number of wired controllers connected to the water  heater.  Controllers need to be wired in parallel.  If four J‐C100 controllers are installed, simultaneously  press the Priority Mode and Power bu ons on the  fourth controller un l a beep sounds.  Number of  Maximum Cable Length for each  Controllers  Controller to Water Heater  1  328   (100 m)  2  164   (50 m)  3 or 4*  65   (20 m)  * Only 3 addi onal controllers can be wired to the  indoor water heater.    Jacuzzi Signature Water Heaters J‐S180/J‐S199  21 ...
  • Página 22: Final Checklist

    Fuel Gas Code, ANSI Z223.1/NFPA 54.  If installed  □  Clean the inlet water filter by closing the cold and  in a manufactured home, the installa on must  hot water inlet isola on (shut‐off) valves.  Put a  conform with the Manufactured Home bucket under the filter at the bo om of the water  Construc on and Safety Standard, Title 24 CFR, heater to catch any water that is contained inside  Part 3280.  the unit.  Unscrew the water filter.  Rinse the  □  Leave the en re manual taped to the water  filter to remove any debris.  Install the filter and  heater (indoor models), temperature controller  open the isola on valves.  (outdoor models),  or give the en re manual  directly to the consumer.  22  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 23: Technical Data

    Electric Connec ons   Temperature Controller: DC 12 Volts (Digital)   Water Temperature Control   Simula on Feedforward and Feedback  Water Supply Pressure   Minimum Water Pressure: 50 PSI (Recommended 60‐80 PSI for maximum performance)   Maximum Water Supply Pressure   150 PSI   Temperature Control Cable   Non‐Polarized Two Core Cable (Minimum 22 AWG)  Energy Star Qualified  Yes    Cer fied for installa on in  Yes  manufactured (mobile) homes  Complies with South Coast Air Quality  Management District 14 ng/J or 20  Yes   No  Yes  Yes  ppm NOx emission levels  * Minimum flow may vary slightly depending on the temperature se ng and the inlet water temperature.      Minimum ac va on flow is 0.4 GPM (1.5 L/min).  Our products are con nually being updated and improved; therefore, specifica ons are subject to change  without prior no ce.  The maximum inlet gas pressure must not exceed the value specified by the manufacturer.  The minimum value  listed is for the purpose of input adjustment.    Jacuzzi Signature Water Heaters J‐S180/J‐S199  23 ...
  • Página 24: Dimensions

    Outdoor Models ‐ J‐SN180W, J‐SP180W, J‐SN199W, J‐SP199W  9.27 (235.5)  0.59 (15)  0.28 (7.2)  14.04 (356.6)  8.90 (226)  B  C  F  G  E  D  DIMENSION  Inches (mm)  DIMENSION  Inches (mm)  A (GAS)  1.31 (33.2)  D  4.33 (110)  A (COLD)  1.93 (49)  E  2.91 (73.8)  A (HOT)  1.35 (34.4)  F  1.61 (40.8)  A  B  3.96 (100.7)  G  2.87 (73)  C  1.17 (29.8)        24  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 25: Pressure Drop And Water Flow Curve

      Informa on for the Service Provider  Pressure Drop Curve   J‐SN199  J‐SN180  J‐SP199  J‐SP180  60.00 55.00 50.00 45.00 40.00 35.00 30.00 25.00 20.00 15.00 10.00 5.00 0.00 Water Flow (gpm)  Outlet Flow Data   J‐SN199  J‐SP199  J‐SN180  J‐SP180  delta T ‐ Temperature Rise (°F)    Jacuzzi Signature Water Heaters J‐S180/J‐S199  25 ...
  • Página 26: Ladder Diagram

        Ladder Diagram                                    26  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 27: Opera On Instruc Ons

      Direct Vent Tankless Water Heater  Opera on Instruc ons  Signature Tankless Water Heaters  J‐SN180F  J‐SN180W  J‐SP180F  J‐SP180W  J‐SN199F  J‐SN199W  J‐SP199F  J‐SP199W  Important Facts about your Water Heater  Thank you for purchasing a Jacuzzi Tankless Water Heater.  For proper opera on and  safety, it is important to follow the instruc ons and adhere to the safety precau ons.    Read all of the instruc ons and the warranty thoroughly before opera ng this water  heater.  Keep this manual in a safe place.  If the informa on in these instruc ons is not followed exactly, a fire or  WARNING explosion may result causing property damage, personal injury or death.  —  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any  other appliance.  —  WHAT TO DO IF YOU SMELL GAS  • Do not try to light any appliance.  • Do not touch any electrical switch; do not use any phone in your building.  • Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s ...
  • Página 28: Consumer Opera On Guidelines For The Safe Opera On Of Your Water Heater

    5.  Locate the manual gas valve on the side of the  8.  Turn on all electric power to the appliance using  the Power bu on.  Manual Valve 9.  Set the thermostat to desired se ng.  CLOSE OPEN 10.  Open a hot water tap.  If the appliance will not  operate, follow the instruc ons “To Turn Off Gas  To Appliance” and call your licensed professional  or gas supplier.  See manual for addi onal  informa on.    TO TURN OFF GAS TO APPLIANCE  1.  Turn off all electric power to the appliance using  3.  Locate the manual gas valve on the side of the  the Power bu on.  heater.  Turn the manual valve clockwise to the  full OFF posi on.  2.  Set the thermostat to lowest se ng.  28  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 29: Opera Ng Instruc Ons

    J‐C200 Spa Controller  The J‐C200 controller is water resistant.  Avoid splashing the controller.  NOTICE  Dimensions (inches):  8.0 W x 4.125 H x 0.875 D  In Use  Temperature  Bath Fill Indicator  Indicator  Display  Priority Mode  Bu on and   Opera on  Indicator  Bu on (Power)  Bath Fill  Bath Fill Power Save  J-C200 Use caution when adjusting wat er temperature. Temperature  Sound  Water Volume  Selec on    Jacuzzi Signature Water Heaters J‐S180/J‐S199  29 ...
  • Página 30: How To Set The Temperature

    If a newly installed unit with a controller  NOTICE  can only be changed while no hot  has not been powered for at least 6 hours  water is running.)  then the temperature will return to the  default se ng of 104° F (40° C) if power is  3.  Press the up (+) or down (‐)  interrupted.  bu ons to obtain the desired  temperature se ng.  There may be a varia on between the  NOTICE    All hot water sources are able to  temperature displayed on the  provide water at this temperature  temperature controller and the  se ng un l it is changed again at  temperature at the tap due to weather  this or another temperature  condi ons or the length of pipe to the  controller.  water heater.  30  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 31 The default temperature se ng for this appliance installed without a temperature controller is 120° F (49° C).  If  desired, the temperature se ng can be changed to 140° F (60° C) by adjustment of a switch.  In the SW1 bank of tan switches, set switch 5 to ON to obtain 140° F water temperature se ng.  Set switch 5 to  OFF (default) to obtain 120° F water temperature se ng.  If a temperature controller is installed, then switch 5 has no effect on temperature se ngs.  Se ng Controller to Mute  On the J‐C100 to eliminate the beeps when keys are pressed or to turn the beeps back on, press and hold both  the up (+) and down (‐) bu ons un l a beep is heard (approximately 5 seconds).  Se ng the Sound Volume (Voice Prompt) on the Spa Controller    J‐C200  Press the “Adjust Sound” bu on to adjust the voice prompt volume.   The default sound  volume is set to Medium.  Each subsequent press of the bu on cycles through the  volume levels in the order below.  Off Volume Off Sound Medium High Volume Low Volume Volume (beep) (no beep)   Jacuzzi Signature Water Heaters J‐S180/J‐S199  31 ...
  • Página 32: Using The Bath Fill Func On

    Loss  If power is lost a er the bath has filled  first  me:  but before the bath fill func on bu on is  Prevent  de‐selected, then the water will not flow  • Over  Monitor and remain by the bath while  during the power loss or a er the power  Filling  the water is running.  is returned.  Once power returns, close  • Use a low bath fill volume less than  the hot water tap and de‐select the bath  25 gallons   fill func on.  No diagnos c code appears.  Do not use with single handle fixtures  NOTICE  that have an ‐scald features built into  An ‐ them.  These fixtures allow a  scald  predetermined amount of cold water  Fixtures  which is not taken into account by the  bath fill func on.  32  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 33: Diagnos C Codes

    The bu on light will go out.  To obtain the outgoing water temperature press the  up (+) or down (‐) bu ons un l “02” displays.  The  temperature will appear in degrees Fahrenheit.  To stop the water flow during the Bath Fill  NOTICE  func on, press the “Bath Fill” bu on.  The  To Stop  bu on will flash and the voice prompt will  No.  Data  Unit  the Bath  announce, “Hot water is not available.   Fill  Turn off all hot water taps and push the  01  Water flow rate  0.1 gal/min  Before it  Bath Fill bu on.”  Follow the voice  02  Outgoing water   Degrees  prompt instruc ons.  Finishes   Fahrenheit  temperature    Jacuzzi Signature Water Heaters J‐S180/J‐S199  33 ...
  • Página 34 Thermal Fuse      Check for restric ons in air flow around unit and vent terminal.  Check gas type of unit and ensure it matches gas type being used.  Check for low water flow in a circula ng system causing short‐cycling.  Ensure dip switches are set to the proper posi on.  Check for foreign materials in combus on chamber and/or exhaust piping.  licensed  Check heat exchanger for cracks and/or separa ons.  professional  Check heat exchanger surface for hot spots which indicate blockage due to scale   only  build‐up.  Refer to instruc ons in manual for flushing heat exchanger.  Hard water   must be treated to prevent scale build up or damage to the heat exchanger.  Measure resistance of safety circuit.  Ensure high fire and low fire manifold pressure is correct.  Check for improper conversion of product.      16    Over Temperature Warning      Check for restric ons in air flow around unit and vent terminal.  licensed  Check for low water flow in a circula ng system causing short‐cycling.  professional  Check for foreign materials in combus on chamber and/or exhaust piping.  only  Check for blockage in the heat exchanger.  34  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 35 Scale Build‐up in Heat  LC #  manual.  Hard water must be treated to prevent scale build up or damage to the heat  Exchanger (when checking  exchanger.  (LC0,  maintenance code history,    To operate the water heater temporarily un l the heat exchanger can be flushed, push the  LC1,  “00” is subs tuted for  Power bu on on the temperature controller 5  mes.  Repeated LC codes will eventually lockout  LC2,…)  “LC#”)   the water heater.  Please call Jacuzzi technical department(1‐888‐835‐9320)   FF  Maintenance Performed    Indicates a service provider performed maintenance or corrected an issue.  Clean inlet water supply filter.    On new installa ons ensure hot and cold water lines are not reversed.  Verify you have at least the minimum flow rate required to fire unit.  Check for cold to hot cross over. Isolate circula ng system if present.  Turn off cold water to the  No  Nothing happens when  unit, open pressure relief valve; if water con nues to flow, there is bleed over in your plumbing.  code   water flow is ac vated.  ...
  • Página 36: Required Maintenance

    2.  Close the water shut off valves.  Remove and clean  “LC#”.)  the water inlet filter.  Snow Accumula on  3.  Remove the front panel by removing 4 screws.    Keep the area around flue terminal free of snow and  4.  Use pressurized air to remove dust from the main  ice.  The appliance will not func on properly if the  burner, heat exchanger, and fan blades.  Do not  intake air or exhaust is impeded (blocked or par ally  use a wet cloth or spray cleaners on the burner.   blocked) by obstruc ons.    Do not use vola le substances such as benzene  and thinners.  They may ignite or fade the paint.  Clean the water filter  5.  Use so  dry cloth to wipe cabinet.    Clean the inlet water filter by closing the cold and hot  Vent System  water inlet isola on (shut‐off) valves.  Put a bucket  under the filter at the bo om of the water heater to  The vent system should be inspected at least annually  catch any water that is contained inside the unit.   for blockages or damage.  Unscrew the water filter.  Rinse the filter to remove  any debris.  Install the filter and open the isola on  valves.  36  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 37: Pressure Relief Valve

    WATER    when opera ng correctly.  The flame must burn with  a clear, blue, stable flame.  See the parts breakdown   Shut off the cold water supply to the water heater.  It  of the burner for the loca on of the view ports.    is generally preferable to shut off the water to the  en re loca on if water is not going to be used.  The flame pa ern should be as shown in the figures  below.  Drain the water heater by opening the drain valves on  the cold water line and hot water line.  Open several hot water taps and remove the filter  assembly at the water inlet in order to allow room for  expansion in case there is water in the lines that  freeze.  ELECTRIC  Disconnect the power supply by either unplugging the  electrical cord or by turning off the circuit breaker to  the water heater to prevent poten al damage from  irregular power surges or interrup ons.  VENT TERMINATION  Place a cover over the vent termina on (intake and  exhaust) if it can be safely accessed.  The cover should  be easy to apply and remove.  This will prevent  debris, leaves, and small animals from entering the  ven ng and water heater which could cause air flow  issues upon return to service.    Jacuzzi Signature Water Heaters J‐S180/J‐S199  37 ...
  • Página 38: Flushing The Heat Exchanger

    8.  Operate the pump and allow the cleaning solu on to  circulate through the water heater for at least 1  hour at a rate of 4 gallons per minute (17.6 liters per  minute).  9.  Turn off the pump.  10.  Rinse the cleaning solu on from the water heater as  follows:  a.  Remove the free end of the drain hose (H3) from  the pail.  Place in sink or outside to drain.  b. Close service valve, (V2), and open shutoff valve,  (V4).  Do not open shutoff valve, (V3).  c.  Allow water to flow through the water heater for  5 minutes.  d.  Close shutoff valve (V4).  When unit has finished  draining remove the in‐line filter at the cold water  inlet and clean out any residue.  Place filter back  into unit and open valve (V4).  e.  Close service valve, (V1),  and open shutoff valve, (V3).  11.  Disconnect all hoses.  12.  Restore electrical power to the                                   water heater.  Following flush procedure call  technical assistance (1‐888‐835‐ 9320 for PCB reset informa on.  Circulating Pump 38  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 39: Manual Draining Of The Water Heater

    5.  Open a tap and confirm that water flows, and then close.  6.  Turn on the power.  7.  A er confirming that the temperature controller is off, turn on the  gas supply.  8.  Turn on the temperature controller.  Running a low volume of water through the water heater to prevent freezing  If the temperature exceeds the ability of the water heater to freeze  protect itself, or if power is lost, the following steps may prevent the  water heater and external piping from freezing.  (Units connected with   COLD J‐LINK (2 unit link) should be drained to prevent freezing if not in use.)  1.  Turn the water heater off.  0.1 gal/min or  2.  Close the gas supply valve.  about 0.2 inch  3.  Turn on a hot water tap to flow water about 0.1 gal/min or where  thick  the stream is about 0.2 inches thick.  When the water heater or external piping has frozen  1.  Do not operate the water heater if it or the external piping is frozen.  2.  Close the gas and water valves and turn off the power.  3.  Wait un l the water thaws.  Check by opening the water supply valve.  4.  Check the water heater and the piping for leaks.    Jacuzzi Signature Water Heaters J‐S180/J‐S199  39 ...
  • Página 40: State Regula Ons

    In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl  space or an a c, the hard wired carbon monoxide detector with alarm and ba ery back‐up may  be installed on the next adjacent floor level.  b.  In the event that the requirements of this subdivision can not be met at the  me of comple on of  installa on, the owner shall have a period of thirty (30) days to comply with the above  requirements; provided, however, that during said thirty (30) day period, a ba ery operated  carbon monoxide detector with an alarm shall be installed.  2.  APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in  accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS  cer fied.   3.  SIGNAGE. A metal or plas c iden fica on plate shall be permanently mounted to the exterior of the  building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent  terminal for the horizontally vented gas fueled hea ng appliance or equipment. The sign shall read, in  print size no less than one‐half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL  OBSTRUCTIONS".  4.  INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled  equipment shall not approve the installa on unless, upon inspec on, the inspector observes carbon  monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1  through 4.   40  Jacuzzi Signature Water Heaters J‐S180/J‐S199 ...
  • Página 41: Replacement Parts

    The Technical Sheet which is located inside the front  cover of the water heater contains a complete  illustrated parts list.    Tech Sheet   Gas Control Assembly  Electrode / Flame Rod  Item No.   Gas Control Assembly  100  Electrode / Flame Rod Kit  116, 117  Fan Assembly / Motor  125  Heat Exchanger  143  Water Flow Servo & Sensor  401  Bypass‐Servo Assembly  403  Fan Assembly / Motor  Heat Exchanger  Water Filter Assy  412  PC Board  700  Ignitor  706  Thermal Fuse Harness  725  Bypass‐Servo Assembly  Water Flow Servo &  Water Filter Assy  PC Board  Sensor  Ignitor  Thermal Fuse Harness    Jacuzzi Signature Water Heaters J‐S180/J‐S199  41 ...
  • Página 42: Consumer Warranty

                            What is covered?  This Warranty covers any defects in materials or workmanship when the product is installed and operated  according to Jacuzzi wri en installa on instruc ons, subject to the terms within this Limited Warranty  document.  This Warranty applies only to products that are installed correctly.  Improper installa on may void  this Warranty.  Jacuzzi strongly suggests that you use a licensed professional who has a ended a product  knowledge class before installing this water heater.  This Warranty extends to the original purchaser and  subsequent owners, but only while the product remains at the site of the original installa on.  This Warranty  only extends through the first installa on of the product and terminates if the product is moved or reinstalled at  a new loca on.  How long does coverage last?  Period of Coverage (from date of purchase)  Item   Residen al Applica ons    Commercial Applica ons  Heat Exchanger  12 years *  5 years * ...
  • Página 43   How do I get service?  You must contact a state qualified/licensed professional for the repair of a product under this Warranty.  For the  name of a licensed professional please contact your place of purchase, visit the Jacuzzi website  (www.jacuzzi.com/tankless), call Jacuzzi at 1‐888‐835‐9320 or write to Jacuzzi at 103 Interna onal Drive,  Peachtree City, Georgia 30269.  Proof of purchase is required to obtain warranty service.  You may register this product within 30 days of  purchase or you may show proof of purchase with a dated sales receipt.  To register your tankless water heater,  .   please visit www.jacuzzi.com/tankless.  For those without internet access, please call 1‐888‐835‐9320 Receipt  of Registra on by Jacuzzi will cons tute proof‐of‐purchase for this product.  However, Registra on is not  necessary in order to validate this Warranty.  What is not covered?  This Warranty does not cover any failures or opera ng difficul es due to the following:  • accident, abuse, or misuse  • altera on  • misapplica on  • force majeure  • improper installa on (such as but not limited to inadequate water quality, condensate damage, improper  ven ng, incorrect gas type, incorrect gas or water pressure, or absence of a drain pan under the appliance)  • improper maintenance (such as but not limited to scale build‐up, freeze damage, or vent blockage)  •...