Installa On Of Ven Ng (Indoor Models) - Jacuzzi J-SN180F Manual De Instalación Y Funcionamiento

Ocultar thumbs Ver también para J-SN180F:
Tabla de contenido

Publicidad

 
Installa on of Ven ng (Indoor Models) 
Install the correct ven ng for your model according to the ven ng manufacturer's instruc ons and the guide‐
lines below. 
Refer to the manufacturer's technical literature for specific part numbers and instruc ons.   
Listed and Tested Vent 
Manufacturer 
Ubbink 
Heat‐Fab 
Metal‐Fab 
Corr/Guard Vent/Air Intake 
  Ven ng Guidelines   
DO NOT 
Do not combine vent components from different 
manufacturers. 
Vent diameter must not be reduced. 
Do not connect the ven ng system with an 
exis ng vent or chimney. 
Do not common vent with the vent pipe of any 
other water heater or appliance. 
MUST DO 
This water heater is a direct vent water heater and 
therefore is cer fied and listed with the vent 
system.  You must use vent components that are 
cer fied and listed with the water heater model. 
The vent system must vent directly to the outside 
of the building and use outside air for combus on. 
Avoid dips or sags in horizontal vent runs by 
installing supports per the vent manufacturer's 
instruc ons. 
Support horizontal vent runs every four feet and 
all ver cal vent runs every six feet or in 
accordance with local codes. 
Ven ng should be as direct as possible with a 
minimum number of pipe fi ngs. 
Vent connec ons must be firmly pressed together 
so that the gaskets form an air  ght seal. 
The vent piece connected to the water heater 
must be secured with one self‐tapping screw. 
 
Products 
Rolux Vent System  
Saf‐T Vent SC system 
System 
 
 
 
Jacuzzi Signature Water Heaters J‐S180/J‐S199 
Telephone 
800‐621‐9419  678‐829‐1666 
800‐772‐0739 
413‐863‐4803 
800‐835‐2830 
316‐943‐2717 
 
 
 
 
 
INFORMATION 
Refer to the instruc ons of the vent system 
manufacturer for component assembly 
instruc ons. 
If the vent system is to be enclosed, it is suggested 
that the design of the enclosure shall permit 
inspec on of the vent system.  The design of such 
enclosure shall be deemed acceptable by the 
installer or the local inspector. 
NOTICE 
If it becomes necessary to access an enclosed vent 
system for service or repairs, Jacuzzi is not 
responsible for any costs or difficul es in accessing 
the vent system.  The warranty does not cover 
obtaining access to a vent system in an enclosed 
environment. 
Fax 
Contact 
www.jacuzzi.com/tankless 
custsvc@heat‐fab.com, 
www.hea ab.com 
info@mtlfab.com, 
www.metal‐fabinc.com 
 
 
 
 
 
 
 
 
13 

Publicidad

Tabla de contenido
loading

Tabla de contenido