Jacuzzi J-SN180F Manual De Instalación Y Funcionamiento página 14

Ocultar thumbs Ver también para J-SN180F:
Tabla de contenido

Publicidad

 
Flue Installa on (Indoor Models)  
Install the ven ng termina on according to the diagrams and instruc ons below. 
WARNING
If the condensate collector is not used, the drain pipe must 
be capped to prevent exhaust gases and condensate from 
entering the building.  The cap is supplied on the appliance. 
Horizontal Termina on using the 
Condensate Collector 
Condensate 
Trap 
Condensate Collector 
14 
Horizontal Termina on without using the Condensate Collector 
3 in (75 mm) 
minimum 
Securing Screw 
Jacuzzi Signature Water Heaters J‐S180/J‐S199 
* The condensate collector must be used in 
horizontal termina ons if a ver cal rise in 
the vent system exceeds 5 . 
Maximum Height * 
5 feet (1.52 m) 
(condensate collector must be used in all installa ons) 
3 in (75 mm) 
minimum 
To adjust the condensate collector posi on or to 
replace the female vent top with a male vent top: 
Bracket 
1.  Loosen the 4 screws at the rear bracket  
2.  Slide the bracket away from the female vent top. 
3.  Remove the 4 screws a aching the female vent top 
to the water heater. 
4.  Li  up the female vent top and reposi on as desired 
(or replace with a male vent top). 
5.  Install the 4 screws at the vent top and  ghten the 4 
screws at the bracket. 
Secure the first vent component to the water heater 
with one self‐tapping screw at the hole located above 
the condensate collector. 
Regions of cold climate will create more 
condensate in the vent system.  The 
condensate collector should be used in 
cold climates. 
If more than one elbow is used in the 
ver cal sec on the condensate collector 
must be used. 
Ver cal Termina on  
Condensate 
Trap 
3 in (75 mm) 
minimum 

Publicidad

Tabla de contenido
loading

Tabla de contenido