Installa On Of Plumbing; Piping Requirements - Jacuzzi J-SN180F Manual De Instalación Y Funcionamiento

Ocultar thumbs Ver también para J-SN180F:
Tabla de contenido

Publicidad

 
Installa on of Plumbing 
Pressure Relief Valve Requirements 
Install a pressure relief valve according to local 
plumbing codes and these instruc ons. 
An approved pressure relief valve is required by the 
American Na onal Standard (ANSI Z21.10.3) for all 
water hea ng systems, and shall be accessible for 
servicing. 
DO NOT 
Do not plug the relief valve and do not install any 
reducing fi ngs or other restric ons in the relief 
line.  The relief line should allow for complete 
drainage of the valve and the line.
Do not place any other type valve or shut off 
device between the relief valve and the water 
 
heater.
MUST DO 
The relief valve must comply with the standard for 
Relief Valves and Automa c Gas Shutoff Devices for
Hot Water Supply Systems ANSI Z21.22 and /or the 
standard Temperature, Pressure, Temperature and
Pressure Relief Valves and Vacuum Relief Valves,
CAN1‐4.4.   
The relief valve must be rated up to 150 psi and to 
at least the maximum BTU/hr of the appliance. 
The discharge from the pressure relief valve should 
be piped to the ground or into a drain system to 
prevent exposure or possible burn hazards to 
humans or other plant or animal life.  Follow local 
codes.  Water discharged from the relief valve 
could cause severe burns instantly, scalds, or 
death. 
The pressure relief valve must be manually 
operated once a year to check for correct 
opera on. 
The relief valve should be added to the hot water 
outlet line and near the hot water outlet according 
to the manufacturer's instruc ons.   DO NOT place 
any other type valve or shut off device between 
the relief valve and the water heater. 
16 
 
Jacuzzi Signature Water Heaters J‐S180/J‐S199 
INFORMATION 
If a relief valve discharges periodically, this may be 
due to thermal expansion in a closed water supply 
system.  Contact the water supplier or local 
plumbing inspector on how to correct this 
situa on.  Do not plug the relief valve. 
The American Na onal Standard (ANSI Z21.10.3)
does not require a combina on temperature and 
pressure relief valve for this appliance.  However, 
local codes may require a combina on 
temperature and pressure relief valve. 
Isola on Valves 
Jacuzzi recommends installa on of isola on valves on 
the cold and hot water lines.  Isola on valves provide 
the ability to isolate the water heater from the 
structure's plumbing and allow quick access to flush 
the heat exchanger.   
Piping Requirements 
A manual water control valve must be placed in the 
water inlet connec on to the water heater before it is 
connected to the water line.  Unions may be used on 
both the hot and cold water lines for future servicing 
and disconnec on of the unit. 
DO NOT 
Do not introduce toxic chemicals such as those 
used for boiler water treatment to the potable 
water used for space hea ng. 
MUST DO 
The piping (including soldering materials) and 
components connected to this appliance must be 
approved for use in potable water systems. 
Purge the water line to remove all debris and air.  
Debris will damage the water heater. 
If the appliance will be used as a potable water 
source, it must not be connected to a system that 
was previously used with a nonpotable water 
hea ng appliance. 
Ensure that the water filter on the water heater is 
clean and installed. 

Publicidad

Tabla de contenido
loading

Tabla de contenido