Connect Electricity 
WARNING
Do not use an extension cord or an adapter plug with 
this appliance. 
The water heater must be electrically grounded in 
accordance with local codes and ordinances or, in the 
absence of local codes, in accordance with the 
Na onal Electrical Code, ANSI/NFPA No. 70. 
Indoor water heaters are equipped with a three‐
prong (grounding) plug for your protec on against 
shock hazard and should be plugged directly into a 
properly grounded three‐prong receptacle.  Do not 
cut or remove the grounding terminal from this plug. 
Do not rely on the gas or water piping to ground the 
water heater.  A screw is provided in the junc on box 
for the grounding connec on. 
The water heater requires 120 VAC, 60 Hz power 
from a properly grounded circuit. 
On indoor models, if using the 5 foot long power 
cord, plug it into a standard 3 prong 120 VAC, 60 Hz 
properly grounded wall outlet.   
On outdoor models, a disconnect switch must be 
provided and installed for the incoming 120 VAC 
power.  It should be a type that is suitable for outdoor 
use.  Check the Na onal Electrical Code, ANSI/NFPA 
70 and your local codes for a proper switch type to 
use in your area. 
The wiring diagram is located on the Technical Sheet 
a ached to the inside of the front cover. 
20 
Jacuzzi Signature Water Heaters J‐S180/J‐S199 
Adjust for High Al tude 
On the DIP switch, set  switches 2 and 3 to the values 
shown in table below for your al tude.  The default 
se ng for the appliance is 0‐2000   (0‐610 m) with 
switches No. 2 and No. 3 in the OFF posi on. 
When the DIP switch is adjusted, it is not necessary to 
adjust the gas pressure se ng for high al tude. 
Al tude 
0‐2000   (0‐610 m) 
2001‐5200   (610‐1585 m) 
5201‐7700   (1585‐2347 m) 
7701‐10200   (2347‐3109 m) 
Adjust for Vent Length  
(indoor models only) 
Adjust switch No. 1 in the SW1 DIP switch (tan 
switches) if required.  Refer to the sec on "Maximum 
 
vent length".
Checklist for Gas and Electricity 
□ 
A manual gas control valve is placed in the gas 
line to the water heater. 
□ 
Check the gas lines and connec ons for leaks. 
□ 
Confirm that the gas inlet pressure is within 
limits. 
□ 
Confirm that the water heater is rated for the gas 
type supplied. 
□ 
Confirm that the electricity is supplied from 120 
VAC, 60 Hz power source and is in a properly 
grounded circuit. 
□ 
An extension cord or an adapter plug has not 
been used with the water heater. 
□ 
For indoor models, verify that switch No. 1 in the 
SW1 DIP switch (tan switches) has been adjusted 
for vent length if necessary.  Refer to the sec on 
on Maximum Vent Length. 
Switch 
Switch 
No. 2 
No. 3 
OFF 
OFF 
OFF 
ON 
ON 
OFF 
ON 
ON 