4
Electrical installation
Wiring
Terminal assignment
Motor
Terminal X105
(right part)
Terminal data
Device sizes I+II:
flexible
with wire end
ferrule
Device size III:
flexible
with wire end
ferrule
44
Labelling
Description
U
Connection of the motor phases
V
W
Connect the shields of the motor phases and of the
optional motor brake control separately and with a
surface as large as possible to the shield sheet. Use
EMC wire clamp or EMC shield clamp for fixing.
Functional earth
Connect the shields of the motor phases and of the
optional motor brake control separately and with a
surface as large as possible to the shield sheet. Use
EMC wire clamp or EMC shield clamp for fixing.
Shield connection/functional earth
SSP940X105
Connection for the PE conductor on the motor side
with M5 ring cable lug
Max. conductor cross-section
2
[mm
]
[AWG]
2.5
12
10
6
Tightening torque
[Nm]
[lb-in]
0.5 ... 0.6
4.5 ... 6.2
1.2 ... 1.5
10.6 ... 13.3
EDK94ZPM113 DE/EN/FR/ES/IT 1.0
Screw driver
PZ0
PZ1