0
3
Fig.7-5
Stripping lengths of the motor cable
Type
Device size I
Device size II
Device size III
How to proceed:
1. Strip the motor cable according to dimensions given.
2. Fold back the shield of the motor cable over the cable sheath.
3. Stabilise the shield with self-adhesive conductive foil
(recommendation).
4. Fix the shield and conductive foil with heat-shrinkable tube on the
cable sheath.
5. Fasten cable lugs or wire end ferrules.
6. Connect the shields separately to the shield sheet using shield clamps (no
strain relief).
EDK94ZPM113 DE/EN/FR/ES/IT 1.0
1
2
c
a
80
90
100
Electrical installation
Terminal assignment
a
d
Dimensions [mm]
b
c
8
25
8
30
10
30
4
Wiring
b
U
V
M5
W
PE
BD1/T1
BD2/T2
e
SSP94MOTL1
d
e
150
8
160
8
170
8
45