- Maximum blinker power
- Power available for photocells and accessories 1A ± 15%
- Power available for radio connector
RADIO SPECIFICATIONS (model T2 24V CRX)
- Receiving Frequency
- Impedance
- Sensitivity
- Pick-up time
- Drop time
300ms
- All inputs must be used as clean contacts because the power is generated internally (secure power) to the board and
is set up to ensure compliance with double or reinforced insulation with regard to dangerous voltage.
- Any external circuits connected to the outputs of the control panel must be made in such a manner as to ensure
compliance with double or reinforced insulation with regard to dangerous voltage.
- All inputs are controlled by a programmed integrated circuit that performs a self check every time it starts operating.
After having carried out the various connections and having supplied voltage, all the LEDS
are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not open or close by activating the various K, Radio, Open and Close
buttons.
The electric lock does not work.
LED DL1 blinks rapidly and no movement is activated.
ACCESSORIES -
L
ONG LEVER
The long lever is suggested for a leaf with a distance up to 500 mm
between the hinge of the leaf and the internal side of the pillar.
S
TRONG BOX FLAT
It is a strong metal (die-cast aluminium) container with lock to protect
manual release and/or push button. It is provided with a rocker switch and
unlocking device (needs cable ACG8022). It has to be fitted onto the wall.
In die-cast aluminium - IP54
resistor in series at 2.2 K ohm)
24Vdc 20W
200Ma
433,92 MHz
52 OHM
>2,24µV
300ms
FAULT
For the connections and the technical data of the optional equipments follow the relevant
handbooks.
code ACG8034
code ACJ9071
T
ROUBLE SHOOTING
After having carried out all connections, by carefully following the layout and having positioned the gate in
intermediate position, check the correct ignition of red LEDS DL7, DL8 and DL9
In case of no ignition of the LEDS, always with gate in intermediate position, check the following and replace any
faulty components.
DL7 switched off Faulty photocells
DL8 switched off Faulty safety edge (In case the edge is not connected, carry out jumper between COM and EDGE)
DL9 switched off Stop button malfunction (if Stop is not connected, perform the jump between COM and STOP).
During functioning with personnel present, with DIP 1 at ON, check that during opening of M1 and M2 the green DL2
and DL4 LEDS switch on and that during closing of M1 and M2 the red DL3 and DL5 LEDS switch on.
Or else, reverse the wires of the motor.
Check fuses F1, FUSE 1.
If the fuse is blown, use only a suitable replacement.
F1 T 2A
TRANSFORMER PROTECTION FUSE (on the outside of the T2 24V
board)
FUSE 1 8A MOTOR PROTECTION FUSE
Check trimmers RUN and LOW-SPEED adjustment.
Make sure that the TCA trimmer is activated with LED DL6 on.
OPEN button always on, replace the OPEN control button or switch.
Sensor Auto test failed, check the connections between the control panel and the sensor power
supply.
Warning: If you are not using a power supply for the sensors, DIP 12 should be OFF.
Faulty safety edge contact. Faulty photocells contact with DIP 4 OFF.
Fix or replace the relative contact.
Ensure to have enabled DIP 8 at ON.
Place dip switches 1, 2 or 3 in the OFF position.
S
TRONG BOX STONE
It is a strong metal (die-cast aluminium) container with lock to protect
manual release and/or push button. It is provided with a rocker switch and
unlocking device (needs cable ACG8022). It has to be embedded in the
wall. In die-cast aluminium - IP54
U
NLOCKING CABLE
Cable for manual releasing the operators from outside, to be connected
to strong box.
35
35
SOLUTION
code ACJ9078
code ACG8022