Description; Area Of Application; Dimensions; Technical Data - Nederman NOM 11 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
3

Description

3.1

Area of application

The filter is to be used with oil vapour only. Other applications are to be
referred to Nederman. If materials containing graphite, lead or chrome are
used, the filters may have to be replaced more frequently.
WARNING!
Explosion risk.
Do not use the unit to separate explosive or combustible material.
3.2

Dimensions

For the dimensions of NOM 11, see Figure 1.
*Measurement depending on extension leg position.
**Internally.
***Externally.
3.3

Technical data

'Table 3-1: Technical data' contains technical data for NOM 11.
Table 3-1: Technical data
Filtration efficiency:
without HEPA filter
with HEPA filter
Operating temperature
Max. air flow
Filter area:
Main filter
HEPA filter
Power
Voltage/rpm
Frequency
Phase
Safety class
Noise level*
Weight
Material recycling
* With silencer, measured according to ISO 11202.
4

Before installation

4.1

Delivery checks

Check the unit for any transport damage. In case of damage or parts missing,
notify the carrier and your local Nederman representative immediately.
NOM 11
>97.5%
>99.97%
5–60 °C
1,100 m
/h
3
8.5 m
2
16 m
2
0.75 kW
See the type label on the motor
50/60 Hz
1~/3~
IP55
66.4 dB(A)
137 kg
86 percent per weight
NOM 11