Technical data

NOTICE
Technical data
Ä
Additional technical data and notices on using the device can be
found in the operating instructions.
CAUTION
UL applications
For UL applications: use is permitted exclusively in Class 2 circuits
according to NEC.
Operating voltage without/with
heating
Power consumption without/with
heating
Light source
Laser class
Wavelength
Impulse duration
Max. output power (peak)
Scanning rate
Working range
Measurement range
Reproducibility (3 sigma)
Interface type
(see 6, page 15)
Service interface
Switching inputs/outputs
Degree of protection
VDE protection class
16
18 ... 30 VDC (PELV, class 2)
Protective Extra Low Voltage (PELV) - protec-
tive extra-low voltage.
≤ 3.7 W / ≤ 17.7 W
Visible red light laser
1 (acc. to IEC 60825-1:2014)
655 nm
≤ 150 µs
≤ 1.8 mW
1000 scans/s
50 ... 170 mm
0 ... 10000 mm
± 0.15 mm
RS 232/RS 422, RS 485, PROFIBUS DP,
SSI, EtherCAT, PROFINET
USB 2.0 (mini-B socket)
2, configurable
IP 65
(Only with MS 3xx, MK 3xx, ME 3xx or KB 30x
connection hood and when M12 connectors or
cable bushings are screwed on and caps are
mounted. Minimum tightening torque of the
housing connecting screw of the connection
hood is 1.4 Nm)